MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/gs-23-428

Медицинская библиотека · Gland surgery · 2024

Normative electromyography data and influencing factors in intraoperative neuromonitoring using adhesive skin electrodes during thyroid surgery.

Shin Sung-Chan, Cheon Yong-Il, Lee Minhyung, Sung Eui-Suk, Lee Jin-Choon, Kim Mijin, Kim Bo Hyun, Lee Byung-Joo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Skin electrodes have been reported to be a useful alternative recording method for intraoperative neuromonitoring (IONM) and show typical electromyography (EMG) waveforms while overcoming the shortcomings of the EMG endotracheal tube. However, the skin electrodes showed relatively lower evoked amplitudes than other recording methods. In this study, we analyzed normative EMG data using skin electrodes and factors that affect the evoked amplitude of thyroid IONM.

METHODS

In total, 167 patients [242 nerves at risk (NAR)] who underwent thyroidectomy under IONM with adhesive skin electrodes were analyzed. A pair of skin electrodes was attached to the lateral border of the lamina of the thyroid cartilage. Evoked EMG data, including mean amplitude and latency, obtained after stimulation of the recurrent laryngeal nerve (RLN) and vagus nerve (VN), were collected and analyzed.

RESULTS

The mean amplitudes of RLN and VN recorded via skin electrodes were 255.48±96.53 and 236.15±69.72 μV, respectively. The mean latency of the right and left RLN was 3.22±0.03 and 3.49±0.08 mS, respectively. The mean latency of the right and left VN was 5.37±0.80 and 7.57±0.10 mS, respectively. The mean amplitude was significantly lower in the obesity, male, and total thyroidectomy (TT) groups. As body mass index (BMI) and age increased, the amplitude of EMG tended to decrease significantly.

CONCLUSIONS

The evoked amplitude recorded with the skin electrodes was relatively low. A larger surgical extent, obesity, male sex, and age >55 years showed significantly lower evoked amplitudes.

Для цитирования: Shin Sung-Chan, Cheon Yong-Il, Lee Minhyung, Sung Eui-Suk, Lee Jin-Choon, Kim Mijin, Kim Bo Hyun, Lee Byung-Joo. Normative electromyography data and influencing factors in intraoperative neuromonitoring using adhesive skin electrodes during thyroid surgery.. Gland surgery. 2024. DOI: 10.21037/gs-23-428.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.