MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-005-0208-z

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2005

Vitreous prolapse and IOL dislocation during intravitreal injection of triamcinolone acetonide.

Degenring Robert F, Sauder Gangolf

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To report on procedure-related anterior segment complications during intravitreal injections.

METHODS

In a prospective interventional case series, 614 eyes received a total of 723 intravitreal injections of about 20 mg triamcinolone acetonide (in 0.2 ml) after paracentesis and aqueous humor drainage for various indications.

RESULTS

In three eyes (0.49% of all eyes) a vitreous prolapse occurred during the injection. In one eye, the vitreous prolapse was combined with dislocation of the intraocular lens (IOL). All three eyes were pseudophakic, showing an posterior capsule defect, and the IOL located in the ciliary sulcus. They were treated by translimbal vitrectomy, and one eye with reposition of the IOL. No other procedure-related postoperative complications were observed during injection or follow-up (7.8+/-7.1 months).

CONCLUSIONS

Intravitreal injections may cause a vitreous prolapse into the anterior chamber with or without IOL decentration or dislocation in predisposed eyes. Ophthalmologists should be aware of this possible complication and inform patients at risk.

Для цитирования: Degenring Robert F, Sauder Gangolf. Vitreous prolapse and IOL dislocation during intravitreal injection of triamcinolone acetonide.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2005. DOI: 10.1007/s00417-005-0208-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.