MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1358863x221094082

Медицинская библиотека · Vascular medicine (London, England) · 2022

Artificial intelligence for the evaluation of peripheral artery disease using arterial Doppler waveforms to predict abnormal ankle-brachial index.

McBane Robert D, Murphree Dennis H, Liedl David, Lopez-Jimenez Francisco, Attia Itzhak Zachi, Arruda-Olson Adelaide, Scott Christopher G, Prodduturi Naresh, Nowakowski Steve E, Rooke Thom W, Casanegra Ana I, Wysokinski Waldemar E, Swanson Keith E, Houghton Damon E, Bjarnason Haraldur, Wennberg Paul W

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with peripheral artery disease (PAD) are at increased risk for major adverse limb and cardiac events including mortality. Developing screening tools capable of accurate PAD identification is a necessary first step for strategies of adverse outcome prevention. This study aimed to determine whether machine analysis of a resting Doppler waveform using deep neural networks can accurately identify patients with PAD.

METHODS

Consecutive patients (4/8/2015 - 12/31/2020) undergoing rest and postexercise ankle-brachial index (ABI) testing were included. Patients were randomly allocated to training, validation, and testing subsets (70%/15%/15%). Deep neural networks were trained on resting posterior tibial arterial Doppler waveforms to predict normal (> 0.9) or PAD (⩽ 0.9) using rest and postexercise ABI. A separate dataset of 151 patients who underwent testing during a period after the model had been created and validated (1/1/2021 - 3/31/2021) was used for secondary validation. Area under the receiver operating characteristic curves (AUC) were constructed to evaluate test performance.

RESULTS

Among 11,748 total patients, 3432 patients met study criteria: 1941 with PAD (mean age 69 ± 12 years) and 1491 without PAD (64 ± 14 years). The predictive model with highest performance identified PAD with an AUC 0.94 (CI = 0.92-0.96), sensitivity 0.83, specificity 0.88, accuracy 0.85, and positive predictive value (PPV) 0.90. Results were similar for the validation dataset: AUC 0.94 (CI = 0.91-0.98), sensitivity 0.91, specificity 0.85, accuracy 0.89, and PPV 0.89 (postexercise ABI comparison).

CONCLUSION

An artificial intelligence-enabled analysis of a resting Doppler arterial waveform permits identification of PAD at a clinically relevant performance level.

Для цитирования: McBane Robert D, Murphree Dennis H, Liedl David, Lopez-Jimenez Francisco, Attia Itzhak Zachi, Arruda-Olson Adelaide, Scott Christopher G, Prodduturi Naresh, Nowakowski Steve E, Rooke Thom W, Casanegra Ana I, Wysokinski Waldemar E, Swanson Keith E, Houghton Damon E, Bjarnason Haraldur, Wennberg Paul W. Artificial intelligence for the evaluation of peripheral artery disease using arterial Doppler waveforms to predict abnormal ankle-brachial index.. Vascular medicine (London, England). 2022. DOI: 10.1177/1358863x221094082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.