m+Medelevator.RU
← Поиск публикаций
Japanese journal of radiology · 2020

Quantitative pharmacokinetic analysis of high-temporal-resolution dynamic contrast-enhanced MRI to differentiate the normal-appearing pituitary gland from pituitary macroadenoma.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kamimura Kiyohisa, Nakajo Masanori, Yoneyama Tomohide, Bohara Manisha, Nakanosono Ryota, Fujio Shingo, Iwanaga Takashi, Nickel Marcel Dominik, Imai Hiroshi, Fukukura Yoshihiko, Yoshiura Takashi

Аннотация

PURPOSE: To evaluate the usefulness of high-temporal-resolution dynamic contrast-enhanced (DCE) MRI and quantitative pharmacokinetic analysis to differentiate the normal-appearing pituitary gland from a pituitary macroadenoma.

MATERIALS AND METHODS: Twenty-seven patients with macroadenomas underwent preoperative DCE-MRI with a temporal resolution of 5 s using compressed sensing to obtain pharmacokinetic parameters. Two independent observers localized the normal-appearing pituitary gland on post-contrast T1-weighted images before and after referring to the corresponding Ktrans maps. Agreements between the localizations and intraoperative findings were evaluated using the kappa statistics. The Mann-Whitney U test was used to compare the pharmacokinetic parameters of the normal-appearing pituitary gland and adenoma.

RESULTS: For both observers, the agreement between the MRI-based localization and the intraoperative findings increased after referring to the Ktrans maps (observer 1, 0.930-1; observer 2, 0.636-0.855). The normal-appearing pituitary gland had significantly higher Ktrans [/min] (1.50 ± 0.80 vs 0.58 ± 0.49, P < 0.0001), kep [/min] (3.19 ± 1.29 vs 2.15 ± 1.18, P = 0.0049), and ve (0.43 ± 0.15 vs 0.25 ± 0.17, P = 0.0003) than adenoma.

CONCLUSION: High-temporal-resolution DCE-MRI and quantitative pharmacokinetic analysis help accurately localize the normal-appearing pituitary gland in patients with macroadenomas. The normal-appearing pituitary gland was characterized by higher Ktrans, kep, and ve than macroadenoma. Dynamic contrast-enhanced MRI with high-temporal-resolution using compressed sensing was used for quantitative pharmacokinetic analysis of pituitary macroadenomas. An observer study, the use of Ktrans maps improved accuracy in localizing the normal-appearing pituitary gland. As compared to an adenoma, the normal-appearing pituitary gland had significantly higher Ktrans, kep, and ve values.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты