m+Medelevator.RU
← Поиск публикаций
Journal of magnetic resonance imaging : JMRI · 2019

Evaluation of image quality of pituitary dynamic contrast-enhanced MRI using time-resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT-TWIST).

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yokota Yusuke, Fushimi Yasutaka, Okada Tomohisa, Fujimoto Koji, Oshima Sonoko, Nakajima Satoshi, Fujii Toshihito, Tanji Masahiro, Inagaki Nobuya, Miyamoto Susumu, Togashi Kaori

Аннотация

BACKGROUND: Time-resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k-space data and view-sharing for the peripheral k-space of dynamic phases. IT-TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction.

PURPOSE: To compare image quality between TWIST and IT-TWIST in 3D pituitary DCE-MRI.

STUDY TYPE: Retrospective observation study.

POPULATION: Fifty-one patients (23 men, 28 women) who underwent 3D pituitary DCE-MRI using TWIST between July 2016 and April 2017.

FIELD STRENGTH/SEQUENCE: 3T/TWIST and IT-TWIST.

ASSESSMENT: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT-TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT-TWIST.

STATISTICAL TESTS: Paired t-test or Wilcoxon rank-sum test was used to test the differences between TWIST and IT-TWIST in both visual evaluation and region of interest evaluation.

RESULTS: Scores of visual evaluations for IT-TWIST were significantly better than those for TWIST (P < 0.001) in all items. Enhancement slope for IT-TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus (P < 0.001). Temporal SD for IT-TWIST was significantly lower than that for TWIST in all items, with statistical significance (P < 0.001).

DATA CONCLUSION: IT-TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE-MRI. Evidence Level: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1497-1506.