Radiofrequency thermal balloon angioplasty in an experimental model of peripheral arterial stenosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sreeram N, Townsend P, Morton D B
Аннотация
RATIONALE: To assess the effect of thermal balloon angioplasty on surgically created peripheral arterial stenoses.
METHODS: Unilateral femoral arterial stenoses were created in 17 neonatal lambs (Dorset X Suffolk/Mule), using absorbable sutures. Six to 8 weeks later, the stenoses were dilated using either a standard (N=5), or thermal balloon angioplasty (N=9). Immediate angiography, flow and pressure gradient measurements were made to assess the acute result following either procedure. The survivors were followed up for a further period of 4 to 6 weeks, and a terminal angiographic study performed. The thermally treated segments of vessels were removed for qualitative histologic analysis.
RESULTS: Thermal angioplasty appeared to be acutely successful in eight of nine animals, compared with one of five successful procedures following standard angioplasty. Higher therapeutic temperatures (> or = 80 degrees C) were associated with vascular complications. At the terminal study, stenoses had recurred in four of six survivors successfully treated with thermal angioplasty. Histologic studies demonstrated non-uniform effects of thermal dilation on the vessel wall, with variable changes ranging from partial or full-thickness tears, fibroblastic or myocyte proliferation, and disorganization of the vessel wall layers.
CONCLUSION: Thermal angioplasty appears to be acutely more beneficial compared with standard angioplasty. However there is a significant recurrence of stenoses, and non-uniform changes in the vessel wall.
METHODS: Unilateral femoral arterial stenoses were created in 17 neonatal lambs (Dorset X Suffolk/Mule), using absorbable sutures. Six to 8 weeks later, the stenoses were dilated using either a standard (N=5), or thermal balloon angioplasty (N=9). Immediate angiography, flow and pressure gradient measurements were made to assess the acute result following either procedure. The survivors were followed up for a further period of 4 to 6 weeks, and a terminal angiographic study performed. The thermally treated segments of vessels were removed for qualitative histologic analysis.
RESULTS: Thermal angioplasty appeared to be acutely successful in eight of nine animals, compared with one of five successful procedures following standard angioplasty. Higher therapeutic temperatures (> or = 80 degrees C) were associated with vascular complications. At the terminal study, stenoses had recurred in four of six survivors successfully treated with thermal angioplasty. Histologic studies demonstrated non-uniform effects of thermal dilation on the vessel wall, with variable changes ranging from partial or full-thickness tears, fibroblastic or myocyte proliferation, and disorganization of the vessel wall layers.
CONCLUSION: Thermal angioplasty appears to be acutely more beneficial compared with standard angioplasty. However there is a significant recurrence of stenoses, and non-uniform changes in the vessel wall.