MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s2724-5683.23.06352-4

Медицинская библиотека · Minerva cardiology and angiology · 2023

Procedural and one-year outcomes following drug-eluting stent and drug-coated balloon combination for the treatment of de novo diffuse coronary artery disease: the HYPER Study.

Buono Andrea, Pellicano Mariano, Regazzoli Damiano, Donahue Michael, Tedeschi Delio, Loffi Marco, Zimbardo Giuseppe, Reimers Bernhard, Danzi Giambattista, DE Blasio Giuseppe, Tespili Maurizio, Ielasi Alfonso

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

De novo diffuse coronary artery disease (CAD) is a challenging scenario in interventional cardiology with limited treatment option, beside stent implantation. In this context, a hybrid approach, combining the use of drug-eluting stent (DES) and drug-coated balloon (DCB) to treat different segments of the same lesion (e.g. long lesion and/or true bifurcation), might be an interesting and alternative strategy to limit the metal amount. The aim of this study was to evaluate the safety and efficacy of a hybrid approach in addressing percutaneous treatment of de novo diffuse CAD.

METHODS

This was a prospective, multicenter study including patients affected by de novo diffuse CAD treated with a hybrid approach from April 2019 to December 2020. Angiographic and clinical data were collected. The primary endpoint was the one-year device-oriented composite endpoint (DOCE, cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization [ID-TLR]). Periprocedural myocardial infarctions and periprocedural success were included among secondary endpoints.

RESULTS

One hundred six patients were included, mean age was 68.2±10.2 years and 78.3% were male. De novo diffuse CAD consisted of 52.8% long lesions and 47.2% true bifurcation lesions. Significant increase in the final minimal lumen diameters and significant decrease in the final diameter stenosis were observed when compared to the baseline values in both DES- and DCB-target segments. Procedural success was 96.2%. DOCE at one-year was 3.7%, with all the adverse events characterized by ID-TLR.

CONCLUSIONS

Combination of DES and DCB could be a safe and effective treatment option for the treatment of de novo diffuse CAD (NCT03939468).

Для цитирования: Buono Andrea, Pellicano Mariano, Regazzoli Damiano, Donahue Michael, Tedeschi Delio, Loffi Marco, Zimbardo Giuseppe, Reimers Bernhard, Danzi Giambattista, DE Blasio Giuseppe, Tespili Maurizio, Ielasi Alfonso. Procedural and one-year outcomes following drug-eluting stent and drug-coated balloon combination for the treatment of de novo diffuse coronary artery disease: the HYPER Study.. Minerva cardiology and angiology. 2023. DOI: 10.23736/s2724-5683.23.06352-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.