MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-23-00330

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2023

Dual-therapy CD34 antibody-covered sirolimus-eluting COMBO stents versus sirolimus-eluting Orsiro stents in patients treated with percutaneous coronary intervention: the three-year outcomes of the SORT OUT X randomised clinical trial.

Jakobsen Lars, Christiansen Evald H, Freeman Phillip, Kahlert Johnny, Veien Karsten, Maeng Michael, Raungaard Bent, Ellert Julia, Villadsen Anton B, Kristensen Steen D, Christensen Martin K, Terkelsen Christian J, Aaroe Jens, Thim Troels, Lassen Jens Flensted, Hougaard Mikkel, Eftekhari Ashkan, Jensen Rebekka V, Støttrup Nicolaj B, Rasmussen Jeppe G, Junker Anders, Jensen Svend E, Hansen Henrik S, Jensen Lisette O

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Target lesion failure (TLF) remains an issue with contemporary drug-eluting stents. The dual-therapy sirolimus-eluting and CD34 antibody-coated COMBO stent (DTS) was designed to improve early healing.

AIMS: We aimed to compare the 3-year outcomes of the DTS and the sirolimus-eluting Orsiro stent (SES) in all-comer patients treated with percutaneous coronary intervention.

METHODS

The SORT OUT X trial is a prospective multicentre randomised clinical trial with a registry-based follow-up comparing DTS and SES. The primary endpoint, TLF, is a composite of cardiac death, myocardial infarction or target lesion revascularisation (TLR).

RESULTS

A total of 3,146 patients were randomised to treatment with the DTS (1,578 patients) or the SES (1,568 patients). At 3 years, an intention-to-treat analysis showed that 155 patients (9.8%) who were assigned the DTS and 118 patients (7.5%) who were assigned the SES met the primary endpoint (incidence rate ratio for TLF=1.33, 95% confidence interval: 1.04-1.70; p=0.02). This difference was caused by a significantly higher TLF rate in the DTS group compared to the SES group within the first year, which was mainly explained by a higher incidence of TLR in the DTS group compared to the SES group. Of note, the TLF rates were almost identical from 1 year to 3 years in both stent groups.

CONCLUSIONS

At 3 years, the SES was superior to the DTS, mainly because the DTS was associated with an increased risk of TLF within the first year but not from 1 to 3 years.

CLINICALTRIALS: gov: NCT03216733.

Для цитирования: Jakobsen Lars, Christiansen Evald H, Freeman Phillip, Kahlert Johnny, Veien Karsten, Maeng Michael, Raungaard Bent, Ellert Julia, Villadsen Anton B, Kristensen Steen D, Christensen Martin K, Terkelsen Christian J, Aaroe Jens, Thim Troels, Lassen Jens Flensted, Hougaard Mikkel, Eftekhari Ashkan, Jensen Rebekka V, Støttrup Nicolaj B, Rasmussen Jeppe G, Junker Anders, Jensen Svend E, Hansen Henrik S, Jensen Lisette O. Dual-therapy CD34 antibody-covered sirolimus-eluting COMBO stents versus sirolimus-eluting Orsiro stents in patients treated with percutaneous coronary intervention: the three-year outcomes of the SORT OUT X randomised clinical trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2023. DOI: 10.4244/eij-d-23-00330.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.