CeRTS: certainty retrieval token search in large language model clinical information extraction.

Schimmelpfennig Lars E, Bhattarai Kriti, Oh Inez Y, Lever Jake, Griffith Obi L, Griffith Malachi, Lai Albert M, Abrams Zachary B

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Large language models (LLMs) must effectively communicate their uncertainty to be viable in clinical settings. As such, the need for reliable uncertainty estimation grows increasingly urgent with the expanding use of LLMs for information extraction from electronic health records. Previous token-level uncertainty estimators have only used token probabilities within a single output sequence. Here, by leveraging the constraints of JSON output structure, we instead consider all likely sequences and their respective probabilities to obtain a more robust measure of model confidence. We develop Certainty Retrieval Token Search (CeRTS), a new uncertainty estimator for structured information extraction.

METHODS

We evaluated CeRTS against a previous gold-standard uncertainty estimator when extracting clinical features from lung cancer discharge summaries across eight open-source LLMs. Calibration (Brier score) and discrimination (AUROC) were used to quantify performance.

RESULTS

CeRTS surpassed the previous gold-standard estimator in discriminatory power across every model and achieved better calibration in most cases. CeRTS had the strongest agreement between model confidence and accuracy with Qwen-2.5.

CONCLUSION

CeRTS enhances LLM-based information extraction from unstructured clinical text by assigning well-calibrated confidence scores to each extracted item, providing medical researchers with a quantitative measure of reliability at minimal additional cost. Although its performance was generally robust, CeRTS struggled with DeepSeek-R1, which we attribute to the model's Chain-of-Thought reasoning steps. Our evaluation focused on clinical data, but CeRTS can be applied to any domain requiring reliable uncertainty estimation.

Для цитирования: Schimmelpfennig Lars E, Bhattarai Kriti, Oh Inez Y, Lever Jake, Griffith Obi L, Griffith Malachi, Lai Albert M, Abrams Zachary B. CeRTS: certainty retrieval token search in large language model clinical information extraction.. Journal of biomedical informatics. 2025. DOI: 10.1016/j.jbi.2025.104900.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.