MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ehj.2017.06.003

Медицинская библиотека · The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2017

Cardiovascular risk of circulating endotoxin level in prevalent hemodialysis patients.

Ibrahim Mohamed, Behairy Maha, El-Ashry Marwa, Mostafa Ahmad E

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiovascular diseases (CVDs) are a major cause of morbidity and mortality in patients with end stage renal disease (ESRD). Circulating endotoxins may have toxic effect on myocardial functions and are speculated as pathogens of accelerated atherosclerosis and hemodialysis (HD) patients.

OBJECTIVE

We aimed to assess the possible relation between circulating endotoxin levels and left ventricular functions parameters, common carotid artery intimal media thickness (CIMT) in prevalent HD patients.

PATIENTS AND

METHODS

Forty stable prevalent HD patients with mean age (47.97 ± 14.42) year using regular conventional hemodialysis sessions in Ain shams university hemodialysis unit, Cairo, Egypt were randomly selected. Diabetics, congestive heart failure and those with history of myocardial infarction or coronary artery disease were excluded from the study. All patients were studied by CBC and routine chemistry, as well as hs CRP, Intact PTH, lipid profile and endotoxin level by ELISA before and after the HD session, Delta change of endotoxin (pre dialysis endotoxin-post dialysis endotoxin) was calculated, resting Doppler echocardiographic and carotid duplex.

RESULTS

Mean of Pre-HD session serum endotoxin level was (0.356 ± 0.090) EU/mL and the mean of post -HD endotoxin levels was (0.367 ± 0.110) EU/mL. Significant positive correlation between post dialysis endotoxin, MV E/A ratio and grades of left ventricular diastolic dysfunction (P < 0.05) and significant correlation between delta change in endotoxin and EF% (r = -0.36,P = 0.02). By stepwise linear regression analysis for determinants of MVE/A post -HD endotoxin level independently associated with MV E/A ratio (ß = 0.350, P = 0.027). We did not detect any significant correlation between CCA atherosclerosis and neither pre nor post- HD endotoxin level nor with delta change of pre and post HD endotoxin levels.

CONCLUSION

Acute increase in post dialytic circulating endotoxin level in prevalent HD patients may be associated with both left ventricular systolic and diastolic dysfunction and that attempts to reduce endotoxin level may have a positive impact on cardiovascular complications in HD Patients.

Для цитирования: Ibrahim Mohamed, Behairy Maha, El-Ashry Marwa, Mostafa Ahmad E. Cardiovascular risk of circulating endotoxin level in prevalent hemodialysis patients.. The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology. 2017. DOI: 10.1016/j.ehj.2017.06.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.