Аннотация

BACKGROUND

Evidence for temporary right ventricular assist devices (tRVADs) is fragmented. We characterized outcomes among adults receiving temporary support for acute right ventricular (RV) failure or RV-predominant cardiogenic shock.

METHODS

MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched from inception to June 2026. Arm-level outcome proportions were pooled on the logit scale using three-level random-effects models, with arms nested within studies. Device-stratified estimates, meta-regression, and sensitivity analyses were examined.

RESULTS

We included 106 studies (119 device arms; 4653 patients), including 57 conference-abstract studies (53.8%). Concurrent left-sided support was reported in 85.8% of patients with available data; post-LVAD RV failure predominated in 47.5% of arms. Separately pooled survival to discharge was 60.4% (95% CI 56.0-64.7; 63 arms), successful weaning 60.6% (54.8-66.2; 68 arms), and 30-day mortality 30.1% (24.1-36.9; 31 arms). The survival prediction interval was wide (34.4%-81.6%). Pooled bleeding, renal complications (acute kidney injury and/or renal replacement therapy, as reported), and stroke were 36.5%, 46.6%, and 14.5%, respectively. Device-stratified estimates were vulnerable to confounding. No meta-regression association remained significant after multiplicity correction.

CONCLUSIONS

These descriptive estimates characterize selected, heterogeneous treated cohorts, predominantly receiving left-sided or biventricular support; they do not establish treatment benefit or comparative device effectiveness. Complication rates were high. Applicability to isolated primary RV shock is limited. Standardized prospective data are needed to inform patient selection, timing, and device strategy.

TRIAL REGISTRATION: PROSPERO registration number: CRD420261406088.

Для цитирования: Elghazaly Hussein, Naeim Omar, Collins Anna, Abouegla Mohamed, Elsiraffy Omar, Maududi Syed Yusuf. Temporary Right Ventricular Mechanical Circulatory Support Devices in Acute Right Ventricular Failure and Cardiogenic Shock: A Cross-Device Systematic Review and Single-Arm Meta-Analysis.. Artificial organs. 2026. DOI: 10.1111/aor.70256.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.