DOI 10.3389/fnagi.2023.1173221

Медицинская библиотека · Frontiers in aging neuroscience · 2023

Age- and time-of-day dependence of glymphatic function in the human brain measured via two diffusion MRI methods.

Han Guangxu, Zhou Ying, Zhang Kemeng, Jiao Bingjie, Hu Junwen, Zhang Yifan, Wang Zejun, Lou Min, Bai Ruiliang

СтатьяПеревод пока не подготовлен

Аннотация

Advanced age, accompanied by impaired glymphatic function, is a key risk factor for many neurodegenerative diseases. To study age-related differences in the human glymphatic system, we measured the influx and efflux activities of the glymphatic system via two non-invasive diffusion magnetic resonance imaging (MRI) methods, ultra-long echo time and low-b diffusion tensor imaging (DTIlow-b) measuring the subarachnoid space (SAS) flow along the middle cerebral artery and DTI analysis along the perivascular space (DTI-ALPS) along medullary veins in 22 healthy volunteers (aged 21-75 years). We first evaluated the circadian rhythm dependence of the glymphatic activity by repeating the MRI measurements at five time points from 8:00 to 23:00 and found no time-of-day dependence in the awake state under the current sensitivity of MRI measurements. Further test-retest analysis demonstrated high repeatability of both diffusion MRI measurements, suggesting their reliability. Additionally, the influx rate of the glymphatic system was significantly higher in participants aged >45 years than in participants aged 21-38, while the efflux rate was significantly lower in those aged >45 years. The mismatched influx and efflux activities in the glymphatic system might be due to age-related changes in arterial pulsation and aquaporin-4 polarization.

Для цитирования: Han Guangxu, Zhou Ying, Zhang Kemeng, Jiao Bingjie, Hu Junwen, Zhang Yifan, Wang Zejun, Lou Min, Bai Ruiliang. Age- and time-of-day dependence of glymphatic function in the human brain measured via two diffusion MRI methods.. Frontiers in aging neuroscience. 2023. DOI: 10.3389/fnagi.2023.1173221.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.