Pan Jie, Wang Jing-Wen, Cai Xiao-Feng, Lu Ke-Feng, Wang Zhen-Zhen, Guo Shun-Yuan
Аннотация
BACKGROUND: There are few reported cases of intracranial large artery embolism due to carotid thrombosis caused by a neck massager. Herein we report such a case.
CASE SUMMARY: A 49-year-old woman presented with left limb weakness and dysarthria after a history of neck massage for 1 mo. Neurological examination showed left central facial paralysis and left hemiparesis with a National Institutes of Health Stroke Scale score of 12. Brain magnetic resonance imaging revealed restricted diffusion on diffusion-weighted imaging in the right parietal and temporal lobes. Computed tomography angiography (CTA) indicated M3 segment embolism of the right middle cerebral artery. Neck CTA revealed thrombosis of the bilateral common carotid arteries. Carotid ultrasound showed thrombosis in the bilateral common carotid arteries (approximately 2 cm below the proximal end of the carotid sinus), and contrast-enhanced ultrasound did not suggest enhancement. No hypertension, diabetes, heart disease, vasculitis, or thrombophilia was found after admission. After 1 wk of treatment with aspirin 200 mg and atorvastatin 40 mg, a carotid ultrasound reexamination showed that the thrombosis had significantly reduced.
CONCLUSION: Neck massager may cause carotid artery thrombosis.
CASE SUMMARY: A 49-year-old woman presented with left limb weakness and dysarthria after a history of neck massage for 1 mo. Neurological examination showed left central facial paralysis and left hemiparesis with a National Institutes of Health Stroke Scale score of 12. Brain magnetic resonance imaging revealed restricted diffusion on diffusion-weighted imaging in the right parietal and temporal lobes. Computed tomography angiography (CTA) indicated M3 segment embolism of the right middle cerebral artery. Neck CTA revealed thrombosis of the bilateral common carotid arteries. Carotid ultrasound showed thrombosis in the bilateral common carotid arteries (approximately 2 cm below the proximal end of the carotid sinus), and contrast-enhanced ultrasound did not suggest enhancement. No hypertension, diabetes, heart disease, vasculitis, or thrombophilia was found after admission. After 1 wk of treatment with aspirin 200 mg and atorvastatin 40 mg, a carotid ultrasound reexamination showed that the thrombosis had significantly reduced.