Ganglion cell complex loss in patients with type 1 diabetes: A 36-month retrospective study.

Thangamathesvaran Loka, Kommana Sumana S, Duong Kim, Szirth Bernard, Khouri Albert S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To analyze changes over a 3-year period in ganglion cell complex (GCC) thickness in individuals with type 1 diabetes mellitus (T1DM) using spectral-domain optical coherence tomography (Optovue, Fremont, CA, USA).

METHODS

Thirty-seven individuals from "Friends for Life Conference" with T1DM and a 3-year history of GCC thickness measurements were included in the study. Data analysis using SPSS 22 and Excel StatPlus was completed to note the subgroups that had a significant change.

RESULTS

Significant decreases were noted in the following subgroups with slope in parenthesis. Overall: GCC superior thickness OD (-0.48)Male: GCC thickness OD (-0.86), GCC superior thickness OD (-0.735)Body mass index (BMI) 25.0-29.9: GCC thickness OD (-0.48), GCC superior thickness OS (-0.915), GCC inferior thickness OD (-0.43)Ages 10-20 years: GCC superior thickness OD (-0.635)Duration of diabetes 10-20 years: GCC thickness OD (-1.055), GCC superior thickness OD (-0.99).

CONCLUSION

GCC loss was noted in individuals who were males, those with BMIs of 25.0-29.9, and those who had diabetes for 10-20 years. Ganglion cell loss was also noted before the presence of any diabetic retinopathy, suggesting onset of neuronal loss before any vasculature changes.

Для цитирования: Thangamathesvaran Loka, Kommana Sumana S, Duong Kim, Szirth Bernard, Khouri Albert S. Ganglion cell complex loss in patients with type 1 diabetes: A 36-month retrospective study.. Oman journal of ophthalmology. 2019. DOI: 10.4103/ojo.ojo_224_2017.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.