MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2020.05.021

Медицинская библиотека · The Journal of surgical research · 2020

Can Resuscitative Endovascular Balloon Occlusion of the Aorta Fly? Assessing Aortic Balloon Performance for Aeromedical Evacuation.

Singer Kathleen E, Morris Mackenzie C, Blakeman Christopher, Stevens-Topie Sabre M, Veile Rosalie, Fortuna Gerald, DuBose Joseph J, Stuever Mary F, Makley Amy T, Goodman Michael D

Оценочное исследованиеСтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Noncompressible torso hemorrhage remains a leading cause of death. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) placement may occur before transport; however, its efficacy has not been demonstrated at altitude. We hypothesized that changes in altitude would not result in blood pressure changes proximal to a deployed REBOA.

METHODS

A simulation model for 7Fr guidewireless REBOA was used at altitudes up to 22,000 feet. Female pigs then underwent hemorrhagic shock to a mean arterial pressure (MAP) of 40 mm Hg. After hemorrhage, a REBOA catheter was deployed in the REBOA group and positioned but not inflated in the no-REBOA group. Animals underwent simulated aeromedical evacuation at 8000 ft or were left at ground level. After altitude exposure, the balloon was deflated, and the animals were observed.

RESULTS

Taking the REBOA catheter to 22,000 ft in the simulation model resulted in a lower systolic blood pressure but a preserved MAP. In the porcine model, REBOA increased both systolic blood pressure and MAP compared with no-REBOA (P < 0.05) and was unaffected by altitude. No differences in postflight blood pressure, acidosis, or systemic inflammatory response were observed between ground and altitude REBOA groups.

CONCLUSIONS

REBOA maintained MAP up to 22,000 feet in an inanimate model. In the porcine model, REBOA deployment improved MAP, and the balloon remained effective at altitude.

Для цитирования: Singer Kathleen E, Morris Mackenzie C, Blakeman Christopher, Stevens-Topie Sabre M, Veile Rosalie, Fortuna Gerald, DuBose Joseph J, Stuever Mary F, Makley Amy T, Goodman Michael D. Can Resuscitative Endovascular Balloon Occlusion of the Aorta Fly? Assessing Aortic Balloon Performance for Aeromedical Evacuation.. The Journal of surgical research. 2020. DOI: 10.1016/j.jss.2020.05.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.