MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1098/rsta.2019.0341

Медицинская библиотека · Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2020

Variability in electrophysiological properties and conducting obstacles controls re-entry risk in heterogeneous ischaemic tissue.

Lawson Brodie A J, Oliveira Rafael S, Berg Lucas A, Silva Pedro A A, Burrage Kevin, Dos Santos Rodrigo Weber

СтатьяПеревод пока не подготовлен

Аннотация

Ischaemia, in which inadequate blood supply compromises and eventually kills regions of cardiac tissue, can cause many types of arrhythmia, some life-threatening. A significant component of this is the effects of the resulting hypoxia, and concomitant hyperklaemia and acidosis, on the electrophysiological properties of myocytes. Clinical and experimental data have also shown that regions of structural heterogeneity (fibrosis, necrosis, fibro-fatty infiltration) can act as triggers for arrhythmias under acute ischaemic conditions. Mechanistic models have successfully captured these effects in silico. However, the relative significance of these separate facets of the condition, and how sensitive arrhythmic risk is to the extents of each, is far less explored. In this work, we use partitioned Gaussian process emulation and new metrics for source-sink mismatch that rely on simulations of bifurcating cardiac fibres to interrogate a model of heterogeneous ischaemic tissue. Re-entries were most sensitive to the level of hypoxia and the fraction of non-excitable tissue. In addition, our results reveal both protective and pro-arrhythmic effects of hyperklaemia, and present the levels of hyperklaemia, hypoxia and percentage of non-excitable tissue that pose the highest arrhythmic risks. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.

Для цитирования: Lawson Brodie A J, Oliveira Rafael S, Berg Lucas A, Silva Pedro A A, Burrage Kevin, Dos Santos Rodrigo Weber. Variability in electrophysiological properties and conducting obstacles controls re-entry risk in heterogeneous ischaemic tissue.. Philosophical transactions. Series A, Mathematical, physical, and engineering sciences. 2020. DOI: 10.1098/rsta.2019.0341.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.