MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.242750

Медицинская библиотека · Radiology · 2025

Noninvasive Tumor Profiling: Quantitative Contrast-Enhanced MRI Markers Predict PD-L1 and CTNNB1 Status in Hepatocellular Carcinoma.

Matuschewski Nickolai J, Sobirey Rabea, Revzin Margarita, Zeevi Tal, Gross Moritz, Kasolowsky Victor, Shewarega Annabella, Meister Ellen, Kao Tabea, Tefera Jonathan, Bousabarah Khaled, Batra Ramesh, Strazzabosco Mario, Lin MingDe, Gebauer Bernhard, Savic Lynn Jeanette, Duncan James, Madoff David C, Zhang Xuchen, Chapiro Julius

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Systemic molecular-targeted therapy is the standard of care for patients presenting with advanced-stage hepatocellular carcinoma (HCC); however, tumor response rates are limited, mainly owing to HCC biomolecular and pathologic heterogeneity. Therefore, novel markers for noninvasive molecular profiling are needed.

PURPOSE: To determine whether advanced image analysis and machine learning on routinely acquired MRI scans can help predict HCC molecular profiles, thereby allowing biomarker-guided treatment allocations.

MATERIALS AND

METHODS

This single-center retrospective study included treatment-naive patients with HCC who underwent tumor resection or liver transplant between September 2006 and February 2022. Multiparametric contrast-enhanced MRI data were obtained, and quantitative and qualitative imaging markers were extracted from lesion and liver segmentations. Pathologic analysis of the resected samples was performed via immunohistochemistry to assess p53 loss of function; catenin beta 1 (CTNNB1) activation; forkhead box M1 activation; and programmed cell death ligand 1 (PD-L1), phosphorylated AKT serine/threonine kinase, phosphorylated SMAD2/3, and sterol O-acyltransferase 1 expression. For each molecular profile outcome, a multivariable logistic regression model was built separately using quantitative imaging, qualitative imaging, or clinical data. The area under the receiver operating characteristic curve (AUC) was used to evaluate model discriminatory performance, and DeLong tests were performed to compare AUCs across models trained on the different data.

RESULTS

Seventy-five patients with T1-weighted, contrast-enhanced, dynamic MRI scans (mean age, 65.7 years ± 9.43 [SD]; 60 males) were included. Receiver operating characteristic curve analysis demonstrated the good discriminatory performance of logistic regression models trained on quantitative imaging data for PD-L1, p53, and CTNNB1, with AUCs of 0.85 (95% CI: 0.74, 0.96), 0.79 (95% CI: 0.66, 0.93), and 0.7 (95% CI: 0.46, 0.93), respectively. Models trained on clinical and qualitative imaging data yielded lower AUCs across profiles, of 0.36 (95% CI: 0.2, 0.53; P < .001) and 0.41 (95% CI: 0.21, 0.62; P = .003), respectively, for p53.

CONCLUSION

Quantitative MRI markers derived from whole tumor and liver volumes can potentially predict p53, PD-L1, and CTNNB1 status in HCC. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Cannella in this issue.

Для цитирования: Matuschewski Nickolai J, Sobirey Rabea, Revzin Margarita, Zeevi Tal, Gross Moritz, Kasolowsky Victor, Shewarega Annabella, Meister Ellen, Kao Tabea, Tefera Jonathan, Bousabarah Khaled, Batra Ramesh, Strazzabosco Mario, Lin MingDe, Gebauer Bernhard, Savic Lynn Jeanette, Duncan James, Madoff David C, Zhang Xuchen, Chapiro Julius. Noninvasive Tumor Profiling: Quantitative Contrast-Enhanced MRI Markers Predict PD-L1 and CTNNB1 Status in Hepatocellular Carcinoma.. Radiology. 2025. DOI: 10.1148/radiol.242750.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.