MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1532-429x-15-61

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2013

Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine.

Halabi Majdi, Faranesh Anthony Z, Schenke William H, Wright Victor J, Hansen Michael S, Saikus Christina E, Kocaturk Ozgur, Lederman Robert J, Ratnayaka Kanishka

СтатьяResearch Support, N.I.H., IntramuralПеревод пока не подготовлен

Аннотация

BACKGROUND

Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance.

METHODS AND

RESULTS

We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals.

CONCLUSIONS

CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in "difficult" pericardial access, for example, in distorted thoracic anatomy or loculated effusion.

Для цитирования: Halabi Majdi, Faranesh Anthony Z, Schenke William H, Wright Victor J, Hansen Michael S, Saikus Christina E, Kocaturk Ozgur, Lederman Robert J, Ratnayaka Kanishka. Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2013. DOI: 10.1186/1532-429x-15-61.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.