Assessing weakness in patients with ulnar neuropathy: comparison between a custom hand muscle dynamometer and a pinch dynamometer.

Allen Matti D, Doherty Timothy J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to compare the use of a custom intrinsic hand dynamometer (HD) with that of a standard pinch dynamometer (PD) in assessing strength in patients with ulnar neuropathy at the elbow.

DESIGN

Nine patients (age, 53 ± 3 yrs) with clinical and electrophysiological features of ulnar neuropathy at the elbow with conduction block (CB) were studied. All underwent bilateral ulnar motor nerve conduction studies recording from the first dorsal interosseous and a quantitative measurement of strength of the first dorsal interosseous using a custom-made HD and a standard PD.

RESULTS

The maximal strength of the ulnar neuropathy at the elbow-affected side (16.2 ± 8.0 N) was found to be significantly lower than that of the unaffected side (27.9 ± 11.2 N), as measured by HD. Strength differences were not significant between the affected (62.7 ± 26.4 N) and unaffected sides (48.0 ± 20.5 N) using PD. HD force decrement (in comparison with the unaffected limb) correlated strongly with CB percentage (r = 0.74). No relationship was found between PD and CB (r = 0.05).

CONCLUSIONS

HD was better able to measure the weakness of affected muscles than did PD, and its results correlated well with the extent of electrophysiological CB. Therefore, a custom HD would provide a better indication of disease severity, progression, or improvement in strength in studies of ulnar neuropathy at the elbow with CB.

Для цитирования: Allen Matti D, Doherty Timothy J. Assessing weakness in patients with ulnar neuropathy: comparison between a custom hand muscle dynamometer and a pinch dynamometer.. American journal of physical medicine & rehabilitation. 2011. DOI: 10.1097/phm.0b013e31822415b6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.