MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.12318

Медицинская библиотека · Clinical implant dentistry and related research · 2015

Structural and Qualitative Bone Remodeling Around Repetitive Loaded Implants in Rabbits.

Kuroshima Shinichiro, Yasutake Munenori, Tsuiki Kotaro, Nakano Takayoshi, Sawase Takashi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Bone mechanical function is regulated by bone quality and bone mineral density (BMD) that reflect bone strength. The preferential alignment of biological apatite (BAp) c-axis/collagen fibers and osteocytes is a determinant factor of bone quality. However, the effect of mechanical loading on bone quality around dental implants is unclear.

PURPOSE: The aim of this study was to clarify the effects of mechanical loading on osseointegration, bone volume BMD, and bone quality around dental implants.

MATERIALS AND

METHODS

Twenty anodized Ti-6Al-4V alloy implants (KYOCERA Co., Kyoto, Japan) were placed in the proximal tibial metaphysis of 10 rabbits. Twelve weeks after surgery, mechanical loading was applied along the long axis of the implant (50 N, 3 Hz, 1,800 cycles, 2 days/week) for 8 weeks. Osseointegration, bone volume, BMD, and bone quality were evaluated using light microscopy, microcomputed tomography, polarized light microscopy, and microbeam X-ray diffractometer.

RESULTS

Mechanical loading increased osseointegration, bone volume, and BMD. Bone quality around dental implant was altered with increased osteocyte numbers and the preferential alignment direction and degree of BAp c-axis/collagen fibers.

CONCLUSIONS

These findings suggest that mechanical loading effectively induces bone anabolic responses around dental implants. Altered bone quality may upregulate bone strength, contributing to long-term implant stability.

Для цитирования: Kuroshima Shinichiro, Yasutake Munenori, Tsuiki Kotaro, Nakano Takayoshi, Sawase Takashi. Structural and Qualitative Bone Remodeling Around Repetitive Loaded Implants in Rabbits.. Clinical implant dentistry and related research. 2015. DOI: 10.1111/cid.12318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.