MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.medengphy.2014.05.015

Медицинская библиотека · Medical engineering & physics · 2014

Finite element analysis of three commonly used external fixation devices for treating Type III pilon fractures.

Ramlee Muhammad Hanif, Kadir Mohammed Rafiq Abdul, Murali Malliga Raman, Kamarul Tunku

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Pilon fractures are commonly caused by high energy trauma and can result in long-term immobilization of patients. The use of an external fixator i.e. the (1) Delta, (2) Mitkovic or (3) Unilateral frame for treating type III pilon fractures is generally recommended by many experts owing to the stability provided by these constructs. This allows this type of fracture to heal quickly whilst permitting early mobilization. However, the stability of one fixator over the other has not been previously demonstrated. This study was conducted to determine the biomechanical stability of these external fixators in type III pilon fractures using finite element modelling. Three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones were reconstructed from previously obtained CT datasets. Bones were assigned with isotropic material properties, while the cartilage was assigned as hyperelastic springs with Mooney-Rivlin properties. Axial loads of 350 N and 70 N were applied at the tibia to simulate the stance and the swing phase of a gait cycle. To prevent rigid body motion, the calcaneus and metatarsals were fixed distally in all degrees of freedom. The results indicate that the model with the Delta frame produced the lowest relative micromovement (0.03 mm) compared to the Mitkovic (0.05 mm) and Unilateral (0.42 mm) fixators during the stance phase. The highest stress concentrations were found at the pin of the Unilateral external fixator (509.2 MPa) compared to the Mitkovic (286.0 MPa) and the Delta (266.7 MPa) frames. In conclusion, the Delta external fixator was found to be the most stable external fixator for treating type III pilon fractures.

Для цитирования: Ramlee Muhammad Hanif, Kadir Mohammed Rafiq Abdul, Murali Malliga Raman, Kamarul Tunku. Finite element analysis of three commonly used external fixation devices for treating Type III pilon fractures.. Medical engineering & physics. 2014. DOI: 10.1016/j.medengphy.2014.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.