MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.1540-8167.2005.40579.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2005

Unsuccessful internal defibrillation in Brugada syndrome: focus on refractoriness and ventricular fibrillation cycle length.

Watanabe Hiroshi, Chinushi Masaomi, Sugiura Hirotaka, Washizuka Takashi, Komura Satoru, Hosaka Yukio, Furushima Hiroshi, Watanabe Hiroshi, Hayashi Junichi, Aizawa Yoshifusa

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

In patients with Brugada syndrome, implantable cardioverter defibrillator (ICD) is the only reliable treatment to prevent sudden death though, in some cases, internal defibrillation may be unsuccessful. The aim of this study was to examine the determinants of defibrillation failure, with a focus on electrophysiologic characteristics.

METHODS

The study included 51 patients treated with ICD: 22 with Brugada syndrome and 29 with structural heart disease (SHD). The prevalence of defibrillation energy requirement precluding the programming of a 10-J safety margin, the mean right ventricular effective refractory period (ERP), and mean induced ventricular fibrillation cycle length (VFCL) from the stored ICD electrograms, were compared between the two patient groups.

RESULTS

High defibrillation requirements were observed in 18% of patients with Brugada syndrome versus 0% of patients with SHD. However, the patients with SHD had larger heart size than those with Brugada syndrome. Mean VFCL and mean ERP were both significantly shorter in patients with Brugada syndrome than in patients with SHD, and ERP and VFCL were significantly correlated.

CONCLUSION

Patients with Brugada syndrome have a high prevalence of high defibrillation energy requirement, and short ventricular ERP and VFCL.

Для цитирования: Watanabe Hiroshi, Chinushi Masaomi, Sugiura Hirotaka, Washizuka Takashi, Komura Satoru, Hosaka Yukio, Furushima Hiroshi, Watanabe Hiroshi, Hayashi Junichi, Aizawa Yoshifusa. Unsuccessful internal defibrillation in Brugada syndrome: focus on refractoriness and ventricular fibrillation cycle length.. Journal of cardiovascular electrophysiology. 2005. DOI: 10.1046/j.1540-8167.2005.40579.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.