MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ogla.2024.01.004

Медицинская библиотека · Ophthalmology. Glaucoma · 2024

Effect of Lens Status on the Outcomes of Glaucoma Drainage Device Implantation.

Stallworth Jeannette Y, Hekmatjah Natan, Yu Yinxi, Oatts Julius T, Ying Gui-Shuang, Han Ying

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: To assess the effect of lens status and cataract surgery on glaucoma drainage device (GDD) efficacy.

DESIGN

Retrospective cohort study.

PARTICIPANTS

Two hundred and forty-three eyes of 216 patients that underwent GDD implantation with ≥1 follow-up visit within 3 years postoperatively. Exclusion criteria included GDD combined with other ophthalmic procedures. 90%-94% of GDDs were Ahmed implants; 83%-90% had adjunctive mitomycin-C.

METHODS

Outcomes were compared between phakic eyes (group A), eyes phakic at time of implantation but subsequently underwent cataract surgery within 3 years (group B), and pseudophakic eyes (group C). Outcomes were measured at 1, 3, 6, 12, 24, and 36 months after tube shunt implantation. Multivariable regression models were performed, adjusting for baseline characteristics.

MAIN OUTCOME MEASURES: Intraocular pressure (IOP) after GDD implantation. Secondary outcomes included change in visual acuity (VA), number of glaucoma eye drops, and rate of failure, defined as additional glaucoma surgery, vision decrease to no light perception, or IOP persistently ≤ 5 mmHg or > 21 mmHg or not reduced from baseline by 20%.

RESULTS

There were 65 eyes in group A, 52 in group B, and 126 in group C. Within group B, cataract surgery was performed at a mean of 1.3 ± 0.7 years after GDD implantation. There were no statistically significant differences in mean IOP or medications between the 3 groups at all time points up to 3 years postoperatively. Significant improvement in VA was noted in groups A and B compared to group C at 6 months, 1 year, and 2 years after implantation; however, by postoperative year 3, change in VA was similar across groups. There were no significant differences in the failure rate amongst groups (P = 0.68). IOP and medications up to 12 months after cataract surgery were similar compared to preoperative baseline. Group B had significantly more short-term (P = 0.02) and long-term (P < 0.001) postoperative complications than groups A or C, driven primarily by hypotony.

CONCLUSIONS

There were no differences in IOP, glaucoma medications, or rate of failure 3 years after GDD implantation based on lens status or after undergoing subsequent cataract surgery. These results may inform the management of patients with co-existing glaucoma and cataract.

FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Для цитирования: Stallworth Jeannette Y, Hekmatjah Natan, Yu Yinxi, Oatts Julius T, Ying Gui-Shuang, Han Ying. Effect of Lens Status on the Outcomes of Glaucoma Drainage Device Implantation.. Ophthalmology. Glaucoma. 2024. DOI: 10.1016/j.ogla.2024.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.