MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0300-8932(02)76669-4

Медицинская библиотека · Revista espanola de cardiologia · 2002

[Dobutamine stress test. Specificity and sensitivity of continuous ST-segment monitoring in 12 simultaneous standard ECG leads].

Beck Edgardo, Santillán Omar, Cecconi Gustavo, De Cicco Andrea, Krasnov Carlos

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVES

This study was designed to evaluate the specificity and sensitivity of the dobutamine stress test with continuous ST-segment monitoring in 12 standard leads.

PATIENTS AND METHOD: We analyzed 75 patients, 36 with unstable angina, 22 post-myocardial infarction angina, 3 after successful angioplasty, 6 chronic stable angina, and 8 atypical chest pain (with normal coronary arteries). All of them underwent coronary angiography (coronary lesions were considering significant with > 70%). Beta-blocking agents, calcium antagonists, and nitrates were discontinued for 48 h before the test. A 12-lead ECG was acquired automatically and ST-segment changes were monitored. Dobutamine infusion started at 5 microgram/kg/min and was increased at 3-minute intervals to 10 microgram, 20 microgram, and a maximum of 40 microgram/kg/min. If heart rate did not reach 85% of the theoretical maximum, 0.5-1 mg atropine was given without discontinuing dobutamine infusion.

RESULTS

Fifty patients (67%) had abnormal coronary arteries (excluding vessels with 100% obstruction) and 25 patients (33%) had normal arteries. In the group of patients with coronary lesions, the test was abnormal in 90% and normal in 10%. In the group of patients with normal arteries, the test was abnormal in 16% and normal in 84%. Consequently, the test had 90% sensitivity, 84% specificity, and 10% false negative and 16% false positive results.

CONCLUSIONS

Our results showed that the dobutamine/ECG test was a simple, effective, and safe bedside tool for diagnosing the severity of coronary disease.

Для цитирования: Beck Edgardo, Santillán Omar, Cecconi Gustavo, De Cicco Andrea, Krasnov Carlos. [Dobutamine stress test. Specificity and sensitivity of continuous ST-segment monitoring in 12 simultaneous standard ECG leads].. Revista espanola de cardiologia. 2002. DOI: 10.1016/s0300-8932(02)76669-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.