Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis.

Scandura Salvatore, Dipasqua Fabio, Gargiulo Giuseppe, Capodanno Davide, Caggegi Anna, Grasso Carmelo, Mangiafico Sarah, Pistritto Anna Maria, Immè Sebastiano, Chiarandà Marta, Ministeri Margherita, Ronsivalle Giuseppe, Cannata Stefano, Arcidiacono Antonio Andrea, Capranzano Piera, Tamburino Corrado

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE).

METHODS

Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume).

RESULTS

In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ± 4.1% at baseline to -11.0 ± 4.4% at follow-up (P = 0.018).

CONCLUSIONS

Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.

Для цитирования: Scandura Salvatore, Dipasqua Fabio, Gargiulo Giuseppe, Capodanno Davide, Caggegi Anna, Grasso Carmelo, Mangiafico Sarah, Pistritto Anna Maria, Immè Sebastiano, Chiarandà Marta, Ministeri Margherita, Ronsivalle Giuseppe, Cannata Stefano, Arcidiacono Antonio Andrea, Capranzano Piera, Tamburino Corrado. Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis.. Journal of cardiovascular medicine (Hagerstown, Md.). 2016. DOI: 10.2459/jcm.0000000000000284.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.