Repair of Stanford type A aortic dissection with ascending aorta and hemiarch replacement combined with stent-graft elephant trunk technique by using innominate cannulation.

Shi Enyi, Gu Tianxiang, Yu Lei, Xiu Zongyi, Zhang Zhiwei, Wang Chun, Fang Qin

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective was to report our experience with a simplified procedure of ascending aorta and hemiarch replacement with a stent-graft elephant trunk in type A dissections. The efficacy of innominate artery cannulation was investigated.

METHODS

From January 2007 to January 2010, 46 patients (35 men, 11 women; mean age, 52.7 ± 12.3 years) with acute type A dissection with 3 vessels of the arch free of lesions received ascending aorta and hemiarch replacement with implantation of a stent graft into the descending aorta under hypothermic circulatory arrest and selective antegrade cerebral perfusion. The innominate artery was used for artery cannulation.

RESULTS

Cardiopulmonary bypass time was 107.9 ± 17.7 minutes, and the time of selective antegrade cerebral perfusion was 35.5 ± 7.1 minutes. The in-hospital mortality was 2.2% (1/46). No permanent neurologic dysfunction and paraplegia were observed. Three patients were lost to follow-up. The average follow-up time was 13.7 ± 7.4 months. Three months after the operation, the false lumen of the distal aorta decreased significantly with thrombosis around the stent graft in all the patients (42/42), at the level of the middle descending aorta in 81.1% (37/42) of the patients, and at the diaphragmatic level in 73.8% (31/42) of the patients. No reoperation related to residual dissected aorta was carried out.

CONCLUSIONS

The simplified procedure of ascending aorta and hemiarch replacement with a stent-graft elephant trunk performed by using innominate artery cannulation is safe and effective in patients with acute type A dissection without involvement of 3 vessels of the arch.

Для цитирования: Shi Enyi, Gu Tianxiang, Yu Lei, Xiu Zongyi, Zhang Zhiwei, Wang Chun, Fang Qin. Repair of Stanford type A aortic dissection with ascending aorta and hemiarch replacement combined with stent-graft elephant trunk technique by using innominate cannulation.. The Journal of thoracic and cardiovascular surgery. 2011. DOI: 10.1016/j.jtcvs.2011.02.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.