MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eijv10i2a35

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2014

Outcomes after revascularisation with everolimus- and sirolimus-eluting stents in patients with acute coronary syndromes and stable angina pectoris: a substudy of the SORT OUT IV trial.

Antonsen Lisbeth, Thayssen Per, Hansen Henrik S, Maeng Michael, Tilsted Hans-Henrik, Bøtker Hans E, Ravkilde Jan, Madsen Morten, Sørensen Henrik T, Thuesen Leif, Lassen Jens F, Jensen Lisette O

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: The aim of this substudy of the SORT OUT IV trial was to compare clinical outcomes among patients with acute coronary syndromes (ACS) and stable angina pectoris (SAP) treated with everolimus-eluting stents (EES) or sirolimus-eluting stents (SES).

METHODS AND

RESULTS

We performed a post hoc subgroup analysis of data from SORT OUT IV. Of 2,705 patients, 1,178 (43.5%) patients had ACS and were treated with EES (n=580) or SES (n=598), and 1,527 (56.5%) patients had SAP and were treated with EES (n=773) or SES (n=754). The primary composite endpoint was major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI), stent thrombosis, or target vessel revascularisation within 18 months. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated for the endpoints. At 18-month follow-up, patients with ACS had higher rates of MACE compared to patients with SAP (8.1% versus 6.7%; HR=1.23, 95% CI: 0.93-1.62). MACE did not differ significantly between ACS patients treated with EES or SES (7.3% versus 8.9%; HR=0.81, 95% CI: 0.54-1.22) nor between SAP patients treated with EES or SES (6.9% versus 6.5%; HR=1.05, 95% CI: 0.71-1.55).

CONCLUSIONS

EES and SES performed similarly with respect to MACE at 18-month follow-up in patients with ACS and SAP.

Для цитирования: Antonsen Lisbeth, Thayssen Per, Hansen Henrik S, Maeng Michael, Tilsted Hans-Henrik, Bøtker Hans E, Ravkilde Jan, Madsen Morten, Sørensen Henrik T, Thuesen Leif, Lassen Jens F, Jensen Lisette O. Outcomes after revascularisation with everolimus- and sirolimus-eluting stents in patients with acute coronary syndromes and stable angina pectoris: a substudy of the SORT OUT IV trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2014. DOI: 10.4244/eijv10i2a35.