Virtual histology intravascular ultrasound analysis of attenuated plaque and ulcerated plaque detected by gray scale intravascular ultrasound and the relation between the plaque composition and slow flow/no reflow phenomenon during percutaneous coronary intervention.
Аннотация
OBJECTIVE
This study aimed to assess the plaque characteristics of attenuated and ulcerated plaques in virtual-histology intravascular ultrasound (VH-IVUS) and the incidence of slow flow/no reflow during percutaneous coronary intervention (PCI).
BACKGROUND
The attenuated and ulcerated plaques are thought as embolic prone plaque; however, the plaque characteristics are unclear.
METHODS
Subjects were 119 patient's 121 lesions undergoing VH-IVUS before coronary stenting. These lesions were divided into the 15 lesions showing attenuated plaque, 24 lesions showing ulcerated plaque, and 82 lesions revealing neither attenuated nor ulcerated plaque (the control group).
RESULTS
Fibro-fatty tissue in the attenuation group was significantly larger than the control group (27.5 ± 9.5% vs 13.9 ± 8.2%, P < 0.01, 3.5 ± 1.9 mm(2) vs 1.6 ± 1.2 mm(2), P < 0.01). Necrotic core in ulceration group was significantly larger than the control group (20.7 ± 9.0% vs 15.9 ± 9.0%, P < 0.05, 2.5 ± 1.3 mm(2) vs 1.7 ± 1.0 mm(2), P < 0.01). Dense calcium in ulceration group was significantly larger than the control group (12.3 ± 6.4% vs 8.3 ± 7.1%, P < 0.05, 1.4 ± 0.7 mm(2) vs 0.9 ± 0.8 mm(2), P < 0.01). In the ulceration group, the necrotic core area of acute coronary syndrome was significantly larger than the stable angina pectoris (3.0 ± 1.4 mm(2) vs 1.8 ± 1.0 mm(2), P < 0.05). The incidence of slow flow/no reflow was significantly higher in the attenuation and ulceration group than the control group (20.0% [3/15], 20.8% [4/24] vs 4.9% [4/82], P < 0.05, 0.05).
CONCLUSION
The attenuated plaque had significantly larger fibro-fatty tissue. The ulcerated plaque had significantly larger necrotic core and dense calcium. The lesions with the attenuated and the ulcerated plaque had more frequent slow flow/no reflow during PCI.