Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021

Meta-analysis comparing valve-in-valve TAVR and redo-SAVR in patients with degenerated bioprosthetic aortic valve.

Saleem Sameer, Ullah Waqas, Syed Mubbasher Ameer, Megaly Michael, Thalambedu Nishanth, Younas Sundas, Zahid Salman, Alam Mahboob, Virani Salim S, Verma Divya Ratan, Abdul-Waheed Mohammad, Fischman David L

СтатьяМетаанализПеревод пока не подготовлен

Аннотация

INTRODUCTION

The comparative efficacy and safety of valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) and redo-surgical AVR (redo-SAVR) in patients with degenerated bioprosthetic aortic valves remain unknown.

METHOD: Digital databases were searched to identify relevant articles. Unadjusted odds ratios for dichotomous outcomes were calculated using a random effect model. A total of 11 studies comprising 8326 patients (ViV-TAVR = 4083 and redo-SAVR = 4243) were included.

RESULTS

The mean age of patients undergoing ViV-TAVR was older, 76 years compared to 73 years for those undergoing SAVR. The baseline characteristics for patients in ViV-TAVR vs. redo-SAVR groups were comparable. At 30-days, the odds of all-cause mortality (OR 0.45, 95% CI 0.30-0.68, p = .0002), cardiovascular mortality (OR 0.44, 95% CI 0.26-0.73, p = .001) and major bleeding (OR 0.29, 95% CI 0.15-0.54, p = .0001) were significantly lower in patients undergoing ViV-TAVR compared to redo-SAVR. There were no significant differences in the odds of cerebrovascular accidents (OR 0.91, 95% CI 0.52-1.58, p = .74), myocardial infarction (OR 0.92, 95% CI 0.44-1.92, p = .83) and permanent pacemaker implantation (PPM) (OR 0.54, 95% CI 0.27-1.07, p = .08) between the two groups. During mid to long-term follow up (6-months to 5-years), there were no significant differences between ViV-TAVR and redo-SAVR for all-cause mortality, cardiovascular mortality and stroke. ViV-TAVR was, however, associated with higher risk of prosthesis-patient mismatch and greater transvalvular pressure gradient post-implantation.

CONCLUSION

ViV-TAVR compared to redo-SAVR appears to be associated with significant improvement in short term mortality and major bleeding. For mid to long-term follow up, the outcomes were similar for both groups.

Для цитирования: Saleem Sameer, Ullah Waqas, Syed Mubbasher Ameer, Megaly Michael, Thalambedu Nishanth, Younas Sundas, Zahid Salman, Alam Mahboob, Virani Salim S, Verma Divya Ratan, Abdul-Waheed Mohammad, Fischman David L. Meta-analysis comparing valve-in-valve TAVR and redo-SAVR in patients with degenerated bioprosthetic aortic valve.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2021. DOI: 10.1002/ccd.29789.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.