Bioprosthetic valve failure. Comparative trial of two balloon-expandable transcatheter heart valve systems in intermediate-risk patients: a propensity score analysis.

Eid-Lidt Guering, Vega Servín Said, Farjat Pasos Julio I, Rivera Rodríguez Agustín, Anaya Morales Carlos A, Marroquin Donday Luis A, Nombela Franco Luis, Gaspar Jorge

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The comparative mid and long-term durability, including the rates of bioprosthetic valve failure (BVF) of the Sapien XT® and Sapien 3® transcatheter heart valve (THV) in patients with intermediate surgical risk has not been reported.

METHODS

Consecutive intermediate-risk patients with severe aortic stenosis from the Mexican registry of transcatheter aortic valve replacement (TAVR) with Sapien® THVs were included. The primary endpoint was to compare the BVF rate between THVs at 2 years of follow-up. Secondary endpoints were comparisons of the composite of global mortality, cardiovascular mortality, and neurological events at 30 d and 24 months of follow-up.

RESULTS

During 2014-2019, 115 (60 Sapien XT® and 55 Sapien 3®) patients met the inclusion criteria in five medical centres. The mean age was 77.3 ± 8.4 years. The average Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) was 5.6 ± 2.9. There was no statistically significant difference between the groups in BVF rate. At 30 d, overall, cardiovascular and non-cardiovascular mortality was 4.3%, 2.6%, and 1.7%, respectively. Neurological events rate was 1.73%. The mean long-term follow-up was 25.3 ± 14.2 months with an overall mortality of 9.56% but lower for the Sapien 3® group (15% vs. 3.6%, p=.037). The only independent predictor of composite mortality and neurological events that occurred in the long term was using a Sapien XT® [OR 1.6, CI 95%, 1.0-24.9; p=.049].

CONCLUSIONS

The BVF rate at 25 months of follow-up was similar with the XT and S3 systems. During this follow-up period, the major composite events of death from any cause and neurological events were significantly lower with the S3 system.

Для цитирования: Eid-Lidt Guering, Vega Servín Said, Farjat Pasos Julio I, Rivera Rodríguez Agustín, Anaya Morales Carlos A, Marroquin Donday Luis A, Nombela Franco Luis, Gaspar Jorge. Bioprosthetic valve failure. Comparative trial of two balloon-expandable transcatheter heart valve systems in intermediate-risk patients: a propensity score analysis.. Acta cardiologica. 2021. DOI: 10.1080/00015385.2021.1894726.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.