BACKGROUND

Transcatheter aortic valve implantation (TAVI) is a safe and beneficial treatment for patients with severe symptomatic aortic stenosis at high and intermediate surgical risk. Success rates for TAVI continue to increase due to more refined procedural approaches and devices, and above all, to the improvements in procedural knowledge by TAVI operators. The development of a new delivery system represents an important evolutionary process in the TAVI procedure, both for the type of device and for the operators, as it may substantially expand indications, success rates, and safety. FlexNav (Abbott Cardiovascular) is a novel delivery system designed to improve ease and precision of TAVI using the Abbott Portico valve. Despite limited results on its advantages, such as those provided in the PORTICO investigational device exemption substudy, uncertainty persists on the actual role of FlexNav in real-world practice.

METHODS AND

RESULTS

We hereby present our preliminary experience with FlexNav in a consecutive series of 18 patients undergoing TAVI with Portico valve in early 2020 (3 with axillary access). Procedural results were excellent, as shown by the absence of deaths, strokes, and major vascular complications (95% confidence interval, 0%-18.5%), and pacemaker implantation in 3 subjects (21.4%; 95% confidence interval, 4.7%-50.8%).

CONCLUSIONS

Despite the small sample size, the present case series suggests that adoption of the FlexNav novel delivery system for TAVI with Portico valve is feasible and safe, and holds the promise of further improving early and long-term results of this procedure.

Для цитирования: Corcione Nicola, Morello Alberto, Ferraro Paolo, Cimmino Michele, Albanese Michele, Ausiello Arturo, Pepe Martino, Biondi-Zoccai Giuseppe, Giordano Arturo. The Novel FlexNav Delivery System for Transcatheter Aortic Valve Implantation With the Portico Device: A Case Series.. The Journal of invasive cardiology. 2021. DOI: 10.25270/jic/20.00513.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.