Minimally invasive aortic valve replacement: short-term efficacy of sutureless compared with stented bioprostheses.

Paparella Domenico, Santarpino Giuseppe, Moscarelli Marco, Guida Pietro, De Santis Adriano, Fattouch Khalil, Martinelli Luigi, Coppola Roberto, Mikus Elisa, Albertini Alberto, Del Giglio Mauro, Gregorini Renato, Speziale Giuseppe

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Sutureless aortic valve prostheses have been introduced to facilitate the implant process, speed up the operating time and improve haemodynamic performance. The goal of this study was to assess the potential advantages of using sutureless prostheses during minimally invasive aortic valve replacement in a large multicentre population.

METHODS

From 2011 to 2019, a total of 3402 patients in 11 hospitals underwent isolated aortic valve replacement with minimal access approaches using a bioprosthesis. A total of 475 patients received sutureless valves; 2927 received standard valves. The primary outcome was the incidence of 30-day deaths. Secondary outcomes were the occurrence of major complications following procedures performed with sutureless or standard bioprostheses. Propensity matched comparisons was performed based on a multivariable logistic regression model.

RESULTS

The annual number of sutureless valve implants increased over the years. The matching procedure paired 430 sutureless with 860 standard aortic valve replacements. A total of 0.7% and 2.1% patients with sutureless and standard prostheses, respectively, died within 30 days (P = 0.076). Cross-clamp times [48 (40-62) vs 63 min (48-74); P = 0.001] and need for blood transfusions (27.4% vs 33.5%; P = 0.022) were lower in patients with sutureless valves. No difference in permanent pacemaker insertions was observed in the overall population (3.3% vs 4.4% in the standard and sutureless groups; P = 0.221) and in the matched groups (3.6% vs 4.7% in the standard and sutureless groups; P = 0.364).

CONCLUSIONS

The use of sutureless prostheses is advantageous and facilitates the adoption of a minimally invasive approach, reducing cardiac arrest time and the number of blood transfusions. No increased risk of permanent pacemaker insertion was observed.

Для цитирования: Paparella Domenico, Santarpino Giuseppe, Moscarelli Marco, Guida Pietro, De Santis Adriano, Fattouch Khalil, Martinelli Luigi, Coppola Roberto, Mikus Elisa, Albertini Alberto, Del Giglio Mauro, Gregorini Renato, Speziale Giuseppe. Minimally invasive aortic valve replacement: short-term efficacy of sutureless compared with stented bioprostheses.. Interactive cardiovascular and thoracic surgery. 2021. DOI: 10.1093/icvts/ivab070.