MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.semtcvs.2021.04.006

Медицинская библиотека · Seminars in thoracic and cardiovascular surgery · 2021

Clinical and Hemodynamic Outcomes of Rapid-Deployment Aortic Bioprostheses.

D'Onofrio Augusto, Tessari Chiara, Cibin Giorgia, Lorenzoni Giulia, Martinelli Gian Luca, Solinas Marco, Gerosa Gino, INTU-ITA group, Gregori Dario, Alamanni Francesco, Polvani Gianluca, Massetti Massimo, Eusanio Marco Di, Merlo Maurizio, Vendramin Igor, Mangino Domenico, Mignosa Carmelo, Russo Claudio, Rinaldi Mauro, De Paulis Ruggero, Pacini Davide, Luzi Giampaolo, Antona Carlo, Salvador Loris, Musumeci Francesco, Maselli Daniele, Colli Andrea, Portoghese Michele, Alfieri Ottavio, De Filippo Carlo Maria

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

Aim of this retrospective, multicenter study was to evaluate early and mid-term clinical and hemodynamic results of patients who underwent surgical aortic valve replacement (SAVR) with Intuity rapid-deployment bioprostheses (RDB) (Edwards Lifesciences, Irvine, CA). We analyzed data from the Italian Registry of Intuity Valve (INTU-ITA registry) that is a national, real-world and independent from the industry registry. Preoperative variables were defined according to EuroSCORE and postoperative outcomes according to Valve Academic Research Consortium (VARC). Survival distribution was evaluated using the Kaplan-Meier approach. A Cox-Proportional Hazard Model was employed to assess the effect of the covariates on patients' survival. The registry included 1687 patients from 23 centers (June 2012-September 2019). Aortic cross clamp time for isolated SAVR was 55 minutes (IQR: 45-70 minute). Postoperative pace-maker rate was 6.3%. At discharge transaortic peak and mean gradients were: 18 mm Hg (IQR: 14-23 mm Hg) and 10 mmHg (IQR: 8-13 mm Hg), respectively. Indexed effective orifice area was 1.10 cm2/m2 (IQR: 0.91-1.31 cm2/m2) and the incidence of severe patient-prosthesis mismatch was 0.6%. Hemodynamic data for all valve sizes remained stable during follow-up. Thirty-day overall mortality was 1.8% (30 patients), and at follow-up it was 5.3% (89 patients). Kaplan-Meier overall survival was 95.5% (94.3-96.7%); 90.7% (88.3-93.1%); 86.4% (82.6-90.4%) at 1, 3, and 5 years, respectively. Serum creatinine (HR: 1.36; 95%CI: 1.04-1.81; p = 0.0397) and cross-clamp time (HR: 1.01; 95%CI: 1.002-1.017; p = 0.0077) were identified as independent predictors of mortality. According to our data from the INTU-ITA registry, SAVR with RDB provides good early clinical and hemodynamic results that are confirmed at follow-up.

Для цитирования: D'Onofrio Augusto, Tessari Chiara, Cibin Giorgia, Lorenzoni Giulia, Martinelli Gian Luca, Solinas Marco, Gerosa Gino, INTU-ITA group, Gregori Dario, Alamanni Francesco, Polvani Gianluca, Massetti Massimo, Eusanio Marco Di, Merlo Maurizio, Vendramin Igor, Mangino Domenico, Mignosa Carmelo, Russo Claudio, Rinaldi Mauro, De Paulis Ruggero, Pacini Davide, Luzi Giampaolo, Antona Carlo, Salvador Loris, Musumeci Francesco, Maselli Daniele, Colli Andrea, Portoghese Michele, Alfieri Ottavio, De Filippo Carlo Maria. Clinical and Hemodynamic Outcomes of Rapid-Deployment Aortic Bioprostheses.. Seminars in thoracic and cardiovascular surgery. 2021. DOI: 10.1053/j.semtcvs.2021.04.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.