MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivab106

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2021

Impact of dialysis in patients undergoing bioprosthetic aortic valve replacement.

Kuroda Yuki, Marui Akira, Arai Yoshio, Nagasawa Atsushi, Tsumaru Shinichi, Arakaki Ryoko, Iida Jun, Wada Yuki, Tamai Yumeka, Fukushima Takashi, Soga Yoshiharu

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine the incidence of bioprosthetic structural valve deterioration in dialysis patients undergoing aortic valve replacement compared to that in patients without dialysis.

METHODS

This single-centre retrospective observational study included 1159 patients who underwent aortic valve replacement using bioprosthetic valves for aortic stenosis and/or regurgitation at our institution between 2007 and 2017 [patients with dialysis (group D, n = 134, 12%) or without dialysis (group N, n = 1025, 88%)]. To adjust for potential differences between groups in terms of initial preoperative characteristics or selection bias, a propensity score analysis was conducted. The final sample that was used in the comparison included 258 patients, as follows: 129 patients with dialysis (group D) and 129 patients without dialysis (group N). The cumulative incidences of all-cause death, cardiac death and moderate or severe structural valve deterioration were estimated using the Kaplan-Meier method.

RESULTS

Operative mortality was significantly higher in group D than group N (9% vs 0%, P = 0.001). Kaplan-Meier analysis revealed that in group D, the incidence was significantly higher for all-cause death (P < 0.001, 50% vs 18% at 5 years), cardiac death (P = 0.001, 18% vs 5% at 5 years) and moderate or severe structural valve deterioration (P < 0.001, 29% vs 5% at 5 years) compared with group N.

CONCLUSIONS

The incidence of structural valve deterioration in dialysis patients undergoing aortic valve replacement was higher than that in patients without dialysis. Bioprosthetic valves should be carefully selected in dialysis patients undergoing aortic valve replacement.

Для цитирования: Kuroda Yuki, Marui Akira, Arai Yoshio, Nagasawa Atsushi, Tsumaru Shinichi, Arakaki Ryoko, Iida Jun, Wada Yuki, Tamai Yumeka, Fukushima Takashi, Soga Yoshiharu. Impact of dialysis in patients undergoing bioprosthetic aortic valve replacement.. Interactive cardiovascular and thoracic surgery. 2021. DOI: 10.1093/icvts/ivab106.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.