MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15569845211004265

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2021

SLL-PEEP Ventilation to Improve Exposure in Minimally Invasive Right Anterolateral Minithoracotomy Aortic Valve Replacement.

Richter Gregor, Van Praet Karel M, Hommel Matthias, Sündermann Simon H, Kofler Markus, Meyer Alexander, Unbehaun Axel, Starck Christoph, Jacobs Stephan, Falk Volkmar, Kempfert Jörg

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

An accepted landmark to assess feasibility of surgical aortic valve replacement (SAVR) via right anterolateral minithoracotomy (RALT) is the aortic-midpoint to right-sternal-edge distance. We aimed to evaluate single left lung positive-end-expiratory-pressure (SLL-PEEP) ventilation inducing an intraoperative rightward shift of the ascending aorta to improve exposure.

METHODS

Nineteen patients with aortic stenosis undergoing SAVR via RALT were prospectively analyzed. SLL-PEEP ventilation (20,395 cmH2O) via a double-lumen endotracheal tube was applied immediately before transthoracic aortic cross-clamping, thereby inducing rightward shift of the ascending aorta to enhance exposure. We analyzed preoperative computed tomography (CT) reconstructions and intraoperative video recordings. Primary endpoint was extent of rightward shift induced by SLL-PEEP ventilation; secondary endpoints were procedure times and safety events.

RESULTS

Mean age was 61 ± 14.8 years and 6 of 19 (31.6%) were female. Mean EuroSCORE II was 0.81% ± 0.04%, STS-PROM was 1.13% ± 0.74%, and mean aortic rightward shift induced by SLL-PEEP ventilation was 10.32 ± 4.14 mm (4 to 17 mm; P = 0.003). Median shift in the group considered suitable for the RALT approach by preoperative CT-scan evaluation was 14.2 mm (IQR 11) and in the less suitable group 11.5 mm (IQR 5). Mean procedure time was 167 ± 28.9 min, CPB time was 105.7 ± 18.4 min, and cross-clamp time was 64.5 ± 13 min. Fifteen patients (79%) received SAVR via RALT with implantation of a bioprosthesis, whereas a rapid-deployment-prosthesis was used in 4 patients (21%). Ten of 19 (53%) patients who were classified as less suitable preoperatively received SAVR via RALT after SLL-PEEP ventilation. No strokes were observed.

CONCLUSIONS

The SLL-PEEP ventilation maneuver during SAVR via RALT significantly enhances aortic exposure. There were no safety events associated with this maneuver and we were able to demonstrate significant rightward aortic shift in every single patient.

Для цитирования: Richter Gregor, Van Praet Karel M, Hommel Matthias, Sündermann Simon H, Kofler Markus, Meyer Alexander, Unbehaun Axel, Starck Christoph, Jacobs Stephan, Falk Volkmar, Kempfert Jörg. SLL-PEEP Ventilation to Improve Exposure in Minimally Invasive Right Anterolateral Minithoracotomy Aortic Valve Replacement.. Innovations (Philadelphia, Pa.). 2021. DOI: 10.1177/15569845211004265.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.