MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajoc.2025.102485

Медицинская библиотека · American journal of ophthalmology case reports · 2025

Intraoperative management of suspected ocular venous air embolism (OVAE) during vitrectomy for retinal detachment.

Helal Birjandi Alireza, Panidou-Marschelke Ermioni, Horn Lisa-Marie, Arlt Kilian, Framme Carsten, Tode Jan

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

report a rare case of ocular venous air embolism (OVAE) occurring during pars plana vitrectomy for retinal detachment and to highlight key intraoperative management steps that led to a successful outcome.

OBSERVATIONS: A 57-year-old patient undergoing 23-gauge vitrectomy developed abrupt hemodynamic instability during air-fluid exchange. Intraoperative signs-including sudden drops in end-tidal CO2 and oxygen saturation-prompted suspicion of air embolism, likely due to suprachoroidal air infusion via a dislodged trocar. Immediate cessation of air infusion, internal tamponade, cardiovascular support, and surgical revision of the infusion system stabilized the patient. Postoperative imaging supported right heart strain consistent with venous air entry. The retinal detachment was successfully treated, and the patient recovered without long-term systemic or ocular complications.

CONCLUSION

This case underscores the potentially fatal risk of OVAE during vitrectomy and the importance of early recognition, prompt intervention, and secure cannula placement. Increased awareness and surgical vigilance are critical for prevention and management of this underreported complication.

Для цитирования: Helal Birjandi Alireza, Panidou-Marschelke Ermioni, Horn Lisa-Marie, Arlt Kilian, Framme Carsten, Tode Jan. Intraoperative management of suspected ocular venous air embolism (OVAE) during vitrectomy for retinal detachment.. American journal of ophthalmology case reports. 2025. DOI: 10.1016/j.ajoc.2025.102485.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.