Endo/epicardial ablation of ventricular arrhythmias with contact force-sensing catheters in arrhythmogenic right ventricular dysplasia/cardiomyopathy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Aras Dursun, Özcan Fırat, Çay Serkan, Özeke Özcan, Kara Meryem, Topaloğlu Serkan
Аннотация
OBJECTIVE: To control ventricular arrhythmia in arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C), ablation may be required both from the endocardial and epicardial side. In this study, we analyzed the results of contact force-sensing (CFS) catheters in the endo/epicardial ablation of ventricular arrhythmias in ARVD/C.
METHODS: We included 17 patients with ARVD/C, 5 of whom had premature ventricular contractions (PVC), and the rest of them were admitted with a ventricular tachycardia (VT) storm, between September 2014 and October 2016. We divided patients into two groups: the PVC and VT groups. Irrigated CFS catheters (Smart Touch, Biosense Webster, Inc.) were utilized in all procedures.
RESULTS: In the PVC group, the mean ratio of PVC during the 24-hour Holter monitoring was 31.8+-7.6%. The mean contact force during mapping and ablation in the right ventricle was 13+-1.2 and 12.8+-1.9 grams, respectively. The mean follow-up duration was 15+-3.1 months for the PVC group. The left ventricular ejection fraction improved in all patients (52.8+-10%). All patients in the VT group underwent endo/epicardial ablation, except one. The mean contact force during the endocardium and epicardium mapping was 12.5+-1.2 and 12.5+-4.6 grams, respectively. The mean contact force during ablation for the endocardium and epicardium was 12.1+-1.4 and 12.8+-1.9 grams, respectively. All clinical and non-clinical VTs were ablated successfully, except in 2 patients who still had non-clinical VTs. The mean follow-up was 15.5+-4.5 months. None of the VT patients experienced electrical storm or death. Two patients had single shock, and 1 patient had two shocks during the follow-up.
CONCLUSION: Endo/epicardial ablation of ventricular arrhythmias with CFS catheters in ARVD/C seems to be promising.
METHODS: We included 17 patients with ARVD/C, 5 of whom had premature ventricular contractions (PVC), and the rest of them were admitted with a ventricular tachycardia (VT) storm, between September 2014 and October 2016. We divided patients into two groups: the PVC and VT groups. Irrigated CFS catheters (Smart Touch, Biosense Webster, Inc.) were utilized in all procedures.
RESULTS: In the PVC group, the mean ratio of PVC during the 24-hour Holter monitoring was 31.8+-7.6%. The mean contact force during mapping and ablation in the right ventricle was 13+-1.2 and 12.8+-1.9 grams, respectively. The mean follow-up duration was 15+-3.1 months for the PVC group. The left ventricular ejection fraction improved in all patients (52.8+-10%). All patients in the VT group underwent endo/epicardial ablation, except one. The mean contact force during the endocardium and epicardium mapping was 12.5+-1.2 and 12.5+-4.6 grams, respectively. The mean contact force during ablation for the endocardium and epicardium was 12.1+-1.4 and 12.8+-1.9 grams, respectively. All clinical and non-clinical VTs were ablated successfully, except in 2 patients who still had non-clinical VTs. The mean follow-up was 15.5+-4.5 months. None of the VT patients experienced electrical storm or death. Two patients had single shock, and 1 patient had two shocks during the follow-up.
CONCLUSION: Endo/epicardial ablation of ventricular arrhythmias with CFS catheters in ARVD/C seems to be promising.