Molecularly imprinted polymer coated Eu-BCA MOF for highly selective detection of Zearalenone in corn oil.

Li Bai, Liao Xiaochen, Wang Li, Chen Yang

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

Based on the strategy of rare-earth MOF coated with molecular imprinted polymer (MIP), a high-performance fluorescent colorimetric sensor was constructed for the detection of Zearalenone (Zen). Bisquinoline acid was selected as the organic ligand to construct the Eu-BCA MOF with europium nitrate, then the quinoline-N in the ligand of MOFs was used to participate in the construction of the SiO2 molecularly imprinted layer to form the Eu-BCA@SiO2-MIP, which can respond quickly to trace Zen in the range of 0-1.56 × 10-6 mol L-1, and the detection limit is as low as 1.66 ng mL-1. The long fluorescence lifetime of Eu enables time-resolved fluorescence detection, which helps to eliminate the interference of various non-specific fluorescence and short-lifetime fluorescence, thereby improving the detection sensitivity and interference immunity. The recovery rate of Zen in corn oil reached 96.88 %-107.40 %. The sensing mechanism was studied by the calculation of Density Functional Theory (DFT) and fluorescence and infrared spectroscopy. Eu-BCA@SiO2-MIP is a sensitive and efficient Zen detection material with superior selectivity, which is of great significance for food safety and grain storage.

Для цитирования: Li Bai, Liao Xiaochen, Wang Li, Chen Yang. Molecularly imprinted polymer coated Eu-BCA MOF for highly selective detection of Zearalenone in corn oil.. Food chemistry. 2025. DOI: 10.1016/j.foodchem.2025.144872.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.