MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ihj.2020.12.014

Медицинская библиотека · Indian heart journal · 2020

Femoral artery access site closure with perclose suture mediated device in coronary interventions.

Bhat Keshavamurthy Ganapathy, Janardhanapillai Ratheesh Kumar, Dabas Ajay Kumar, Chadha Davinder Singh, Swamy Ajay Jagannath, Chadha Amitoj Singh

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the outcome of suture mediated vascular closure device Perclose Proglide (PP) with manual compression (MC) following transfemoral access for coronary interventions (CI).

METHODS

It is a retrospective, observational, single centre study from January 2018 to September 2019. Consecutive patients undergoing interventions through transfemoral access were divided into PP and MC groups. Those with less than 3 months follow up were excluded. Two groups were compared for baseline characteristics and various complications at 24 h and at 30 days.

RESULTS

Out of 1743 patients studied, PP group included 1343 and MC group, 400 patients. Both groups were comparable in baseline characteristics, sheath size and use of antiplatelets and anticoagulation. PP group had significantly less minor bleeding (P = .01, CI 0.34-4.03) and hematoma (P = .0007, CI 0.95-5.10) at 24 h. At 30 days, minor bleeding (P < .0001, CI 0.97-4.25), hematoma (P = .0002, CI 1.05-4.93) and pseudo-aneurysm (P = .0095, CI 0.03-1.18) were also significantly less in PP group. Obesity (OR 3.5, CI 1.29-9.49) and hypertension (OR 2.41, CI 1.12-5.19) were associated with increased minor bleeding at 24 h. Device failure rate was 2.38%.

CONCLUSIONS

PP device is safe, effective and is associated with fewer complications than MC in CI. Device failure rate is low. Obesity and hypertension are associated with increased minor bleeding in both groups.

Для цитирования: Bhat Keshavamurthy Ganapathy, Janardhanapillai Ratheesh Kumar, Dabas Ajay Kumar, Chadha Davinder Singh, Swamy Ajay Jagannath, Chadha Amitoj Singh. Femoral artery access site closure with perclose suture mediated device in coronary interventions.. Indian heart journal. 2020. DOI: 10.1016/j.ihj.2020.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.