BACKGROUND

Advancements in minimally invasive surgical ablation (MISA) have focused on improving pulmonary vein isolation. Additional ablation targets have been developed (such as posterior wall isolation). The mid- and long-term effects of current techniques (including electrophysiologic findings and recurrent arrhythmia mechanisms) have not previously been reported.

METHODS

Twenty eight patients with recurrent atrial arrhythmias after bipolar clamp ablation of the pulmonary vein antrum, ganglionated plexi, posterior wall isolation (roof and floor lines to create a posterior box), and ligament of Marshall ligation/cauterization and left atrial appendage clipping underwent follow up electrophysiology study including left atrial mapping an average of 2.3 years postoperatively.

RESULTS

Atrial fibrillation was the most common recurrent arrhythmia (n = 18) followed by micro-reentrant atrial tachycardia (n = 5), macro-reentry left atrial flutter (n = 3), and typical cavo-tricuspid isthmus atrial flutter (n = 2). Eighty six of 112 (77%) PVs mapped were electrically isolated, 16 (57%) patients had all four pulmonary veins (PVs) isolated. The posterior wall (PW) was completely isolated in only four (14%) patients, seven (25%) patients had normal PW voltage, while 17 (61%) patients had abnormal delayed or fractionated electrograms in the posterior wall (incomplete isolation). Abnormal PW electrograms were more frequently found in patients with complex recurrent left atrial arrhythmia (micro-reentry or left atrial macro-reentry flutter).

CONCLUSION

With current surgical techniques PV isolation has improved, but PW isolation remains challenging. Incomplete PW isolation may produce arrhythmogenic substrate.

Для цитирования: Larsen Timothy R, Koneru Jayanthi N, Padala Santosh K, Kasirajan Vigneshwar, Ellenbogen Kenneth A. Spectrum of arrhythmogenic substrate post minimally invasive maze surgery in patients with recurrent.. Pacing and clinical electrophysiology : PACE. 2021. DOI: 10.1111/pace.14242.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.