MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2014.02.008

Медицинская библиотека · Journal of cardiology · 2014

Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement.

Yamanaga Kenshi, Tsujita Kenichi, Shimomura Hideki, Nakamura Yoshinori, Ogura Yuji, Onoue Yoshiro, Chazono Naomi, Nagata Takeshi, Morisaki Shogo, Kudo Takashi, Yamada Yoshihiro, Komura Naohiro, Miyazaki Takashi, Akasaka Tomonori, Horio Eiji, Sato Koji, Arima Yuichiro, Kojima Sunao, Kaikita Koichi, Tayama Shinji, Hokimoto Seiji, Ogawa Hisao

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: In-stent restenosis has been decreasing through the introduction of drug-eluting stents (DES). On the other hand, adverse events such as very late stent thrombosis (VLST) and late catch-up phenomenon can occur especially with sirolimus-eluting stents (SES, first-generation DES) in long-term follow-up. However, the precise mechanisms underlying VLST have not been well investigated in vivo.

METHODS AND

RESULTS

From 2004 to 2010, 2034 SES were implanted in 1656 patients and caused eight VLST (0.48% per patient) at Fukuoka Tokushukai Medical Center. Of these, serial intravascular ultrasound (IVUS) images (post-stent implantation and at the time of VLST onset) were obtained from three patients with VLST. Comparing them with eight control patients with SES implanted, the vascular reactivity of VLST patients was analyzed. Eight VLST happened 50 ± 15 months after stent implantation and three of the eight patients with VLST had not taken aspirin daily. There were no differences in minimum stent area, maximum external elastic membrane (EEM) area, and stent edge (distal and proximal) EEM area in post-procedural IVUS images. Compared with the control group patients, ΔEEM area (10.6 ± 3.4mm(2) vs. 1.7 ± 1.9 mm(2), p=0.01) and vessel expansion ratio (185.6 ± 40.3% vs. 112.0 ± 12.1%, p=0.01) were significantly greater in the VLST group based on the greater peri-stent plaque expansion (262.1 ± 72.8% vs. 118.7 ± 21.2%, p=0.01).

CONCLUSION

Our serial IVUS study showed that the vascular positive remodeling after SES implantation is one of the most probable morphological mechanisms for VLST development.

Для цитирования: Yamanaga Kenshi, Tsujita Kenichi, Shimomura Hideki, Nakamura Yoshinori, Ogura Yuji, Onoue Yoshiro, Chazono Naomi, Nagata Takeshi, Morisaki Shogo, Kudo Takashi, Yamada Yoshihiro, Komura Naohiro, Miyazaki Takashi, Akasaka Tomonori, Horio Eiji, Sato Koji, Arima Yuichiro, Kojima Sunao, Kaikita Koichi, Tayama Shinji, Hokimoto Seiji, Ogawa Hisao. Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement.. Journal of cardiology. 2014. DOI: 10.1016/j.jjcc.2014.02.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.