MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ihj.2013.12.038

Медицинская библиотека · Indian heart journal · 2014

A prospective study evaluating efficacy of polymer free Pronova XR stent in treatment of denovo coronary artery stenosis.

Deshpande N V, Admane Parag, Deshpande Mohan, Mardikar H M

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Drug eluting stents have remarkably improved results of percutaneous coronary angioplasty. Most of the currently available drug eluting stents uses a durable polymer as drug carrier which has been implicated in local inflammatory response and continued incidence of late and very late stent thrombosis. The Pronova XR stent is one from those new generation polymer free sirolimus eluting stents in which pharmaceutical excipient is used for the timed release of sirolimus from the XR stent platform instead of a polymeric coating.

METHODOLOGY: We consecutively recruited 121 patients undergoing elective or urgent PCI at our center. All the patients were followed up clinically and mandatory follow up angiogram at 6 months was done for one third of the total patients. An independent core lab analyzed paired angiograms.

RESULTS

The primary efficacy endpoint was death, MI, TVR at 6 months which occurred in 6.66% patients. The QCA analysis showed reference vessel diameter of 2.5 + 0.44 mm at baseline and the minimal luminal diameter was 0.88 + 0.43 mm giving baseline diameter stenosis of 65.26 + 15.89%. The immediate post procedure in-segment diameter stenosis assessed was 23.68 + 8.96% which increased to 36.02 + 24.48% at follow up with a late lumen loss of 0.25 + 0.76 mm at mean of 191 days.

CONCLUSION

Coronary angioplasty with polymer free Pronova XR stents results in acceptable late lumen loss and very low target lesion revascularisation at short and intermediate term in unselected patients.

Для цитирования: Deshpande N V, Admane Parag, Deshpande Mohan, Mardikar H M. A prospective study evaluating efficacy of polymer free Pronova XR stent in treatment of denovo coronary artery stenosis.. Indian heart journal. 2014. DOI: 10.1016/j.ihj.2013.12.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.