OBJECTIVES

To compare a new stent with an asymmetric coating, eluting the drug to the abluminal surface, to a stent with a conventional coating eluting the drug both to the luminal and the abluminal side.

BACKGROUND

Stents with asymmetric coating, eluting the drug to the vessel wall (BPSES-A), could potentially give faster reendothelialization after percutaneous coronary interventions (PCI) and decrease in in-stent thrombosis and late restenosis.

METHODS

BPSES-A, conventional coated stents (BPSES-C), biodegradable polymer stents without drug (BPS, for control), and bare metal stents (BMS, for control) were implanted into the coronary arteries of 38 pigs (75 stents). Pigs were sacrificed after 4, 12, and 24 weeks. Quantitative coronary angiography was used to compare in-stent late lumen loss (LLL) and electron microscopy was used to reveal levels of reendothelialization.

RESULTS

The stents were all successfully implanted. LLL of BPSES-A, BPSES-C, BMS, and BPS were 0.56 ± 0.51, 0.60 ± 0.58, 0.89 ± 0.43, and 1.68 ± 0.30 mm, respectively, after 4 weeks. LLL of BPSES-A and BPSES-C were 0.63 ± 0.53 and 0.69 ± 0.24 mm, respectively, after 12 weeks. LLL of BPSES-A, BPSES-C, and BMS were 0.42 ± 0.15 m, 0.56 ± 0.28 mm, and 0.99 ± 0.13 mm, respectively, after 24 weeks. The scaling of reendothelialization was as follows: after 4 weeks BMS > = BPS > BPSES-A > BPSES-C, after 12 weeks BPSES-A > BPSES-C, and after 24 weeks BMS > BPSES-A > BPSES-C. Reendothelialization was better in BPSES-A than BPSES-C (P < 0.05). There was no correlation between LLL and reendothelialization (P = 0.42).

CONCLUSION

Asymmetric coating of coronary stents might be helpful to improve reendothelialization. © 2016 Wiley Periodicals, Inc.

Для цитирования: Zhang Haijun, Deng Wei, Wang Xiangfei, Wang Shenguo, Ge Junbo, Toft Egon. Solely abluminal drug release from coronary stents could possibly improve reendothelialization.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.25335.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.