DOI 10.1002/ccd.25542

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2014

One-year follow-up of patients treated with new-generation polymer-based 38 mm everolimus-eluting stent: the P38 study.

Sgueglia Gregory A, Belloni Flavia, Summaria Francesco, Conte Micaela, Cortese Bernardo, Silva Pedro Leon, Ricci Roberto, Lioy Ernesto, Pucci Edoardo, Gaspardone Achille

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the clinical outcome at 1-year follow-up of real-world patients with long coronary lesions treated with the 38 mm Xience Prime (Abbott Vascular) everolimus-eluting stent (EES).

BACKGROUND

Long-lesions present special challenges to the interventional cardiologists, including increased risk of restenosis, periprocedural injury, geographical miss, and stent deliverability. Indeed, results obtained with shorter stent in the treatment of simpler lesions are of limited applicability to longer stents.

METHODS

Consecutive patients presenting with a long coronary lesion treated by percutaneous coronary intervention with at least one implanted 38 mm EES were enrolled in the study. Their clinical data were prospectively registered. Major adverse cardiac events (MACE) were defined as a composite of cardiac death, nonfatal myocardial infarction (according to the Universal Definition) and target vessel revascularization. Stent thrombosis was defined according to the Academic Research Consortium criteria.

RESULTS

Overall, 203 real-world patients (152 men, 68 ± 9 years) were enrolled in the P38 Study. At 1-year follow-up, 6 (3.0%) patients had died from cardiac causes, 7 (3.4%) had a nonfatal myocardial infarction and 8 (3.9%) underwent target vessel revascularization, yielding a 10.3% cumulative rate of MACE. Two patients had a stent thrombosis (one definite and one probable). No significant differences in event rates were found between patients with and without an additional stent implanted overlapping the 38 mm one.

CONCLUSIONS

The use of a new-generation polymer-based 38 mm EES in a real-world population with unselected long lesions is associated with excellent procedural results and good clinical outcomes at 12-month follow-up.

Для цитирования: Sgueglia Gregory A, Belloni Flavia, Summaria Francesco, Conte Micaela, Cortese Bernardo, Silva Pedro Leon, Ricci Roberto, Lioy Ernesto, Pucci Edoardo, Gaspardone Achille. One-year follow-up of patients treated with new-generation polymer-based 38 mm everolimus-eluting stent: the P38 study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2014. DOI: 10.1002/ccd.25542.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.