Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2014
A combination of plaque components analyzed by integrated backscatter intravascular ultrasound and serum pregnancy-associated plasma protein a levels predict the no-reflow phenomenon during percutaneous coronary intervention.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Daidoji Hyuma, Takahashi Hiroki, Otaki Yoichiro, Tamura Harutoshi, Arimoto Takanori, Shishido Tetsuro, Miyashita Takehiko, Miyamoto Takuya, Watanabe Tetsu, Kubota Isao
Аннотация
AIMS: Previous studies reported that integrated backscatter intravascular ultrasound (IB-IVUS) provides high diagnostic accuracy for tissue characterization of coronary plaques and that pregnancy-associated plasma protein A (PAPP-A) could be a marker of adverse cardiac outcome in patients with cardiovascular disease. We examined whether IB-IVUS and PAPP-A levels could predict the incidence of no-reflow during percutaneous coronary intervention (PCI) METHODS AND RESULTS: About 176 consecutive patients (138 men, mean age 68 ± 11 years) who underwent PCI with IB-IVUS were prospectively enrolled. Combined no-reflow, including transient filter no-reflow by using distal protection devices, was observed in 31 patients. The percentages of coronary lipid volume (%LV) analyzed by IB-IVUS and serum PAPP-A were significantly higher in patients with combined no-reflow than normal-reflow. To predict no-reflow, a receiver operating characteristic (ROC) analysis determined cut-off values of %LV as 62% and serum PAPP-A as 7.71 ng/mL. The multivariate logistic regression analysis showed that %LV (hazard ratio 4.5, 95% confidence interval 1.6-13.4, P < 0.01) and PAPP-A (hazard ratio 4.32, 95% confidence interval 1.5-12.7, P < 0.01) were independent predictors of combined no-reflow
CONCLUSIONS: %LV analyzed by IB-IVUS and serum PAPP-A levels were closely associated with the coronary no-reflow phenomenon. © 2014 Wiley Periodicals, Inc.
CONCLUSIONS: %LV analyzed by IB-IVUS and serum PAPP-A levels were closely associated with the coronary no-reflow phenomenon. © 2014 Wiley Periodicals, Inc.
Предметные рубрики MeSH
AgedArea Under CurveBiomarkersCoronary Artery DiseaseCoronary CirculationCoronary VesselsFemaleHumansLogistic ModelsMaleMiddle AgedMultivariate AnalysisNo-Reflow PhenomenonPercutaneous Coronary InterventionPlaque, AtheroscleroticPredictive Value of TestsPregnancy-Associated Plasma Protein-AProportional Hazards ModelsProspective StudiesROC CurveRisk FactorsTreatment OutcomeUltrasonography, Interventional