MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14814/phy2.15920

Медицинская библиотека · Physiological reports · 2024

Evaluation of ventricular-vascular coupling with critical care metrics: An in silico approach.

Mulligan Lawrence J, Ungerleider Justin, Friedman Adam, Sanders Benjamin, Thrash Julian, Ewert Daniel, Mitrev Ludmil, Hill Jeffrey C

СтатьяПеревод пока не подготовлен

Аннотация

Mean arterial pressure and cardiac output provide insufficient guidance for the management of intraoperative hypotension (IOH). In silico models offer additional insights into acute changes in hemodynamic parameters that may be encountered during IOH. A computational model (CM) generated parameters quantifying ventricular-vascular coupling, and pressure-volume construct across levels of aortic compliance (CA ). We studied how a loss from normal-to-stiff CA impacts critical care metrics of hemodynamics during vascular occlusion. Pulse pressure (PP), end-systolic pressure (Pes ), arterial compliance (Art-ca), arterial elastance (Art-ea), and dynamic arterial elastance (Eadyn), along mechanical efficiency (ME) were measured at five levels of CA . A loss in CA impacted all variables. During steady-state conditions, PP, Pes , and stroke work increased significantly as CA decreased. Art-ca decreased and Art-ea increased similarly; Eadyn increased and ME decreased. During a decrease in preload across all CA levels, arterial dynamics measures remained linear. The CM demonstrated that a loss in CA impacts measures of arterial dynamics during steady-state and transient conditions and the model demonstrates that critical care metrics are sensitive to changes in CA . While Art-ca and Art-ea were sensitive to changes in preload, Eadyn did not change.

Для цитирования: Mulligan Lawrence J, Ungerleider Justin, Friedman Adam, Sanders Benjamin, Thrash Julian, Ewert Daniel, Mitrev Ludmil, Hill Jeffrey C. Evaluation of ventricular-vascular coupling with critical care metrics: An in silico approach.. Physiological reports. 2024. DOI: 10.14814/phy2.15920.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.