Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.

Costopoulos Charis, Latib Azeem, Naganuma Toru, Sticchi Alessandro, Ferrarello Santo, Regazzoli Damiano, Chieffo Alaide, Figini Filippo, Carlino Mauro, Montorfano Matteo, Naim Charbel, Kawaguchi Masanori, Gerasimou Argyrios, Giannini Francesco, Godino Cosmo, Colombo Antonio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions.

BACKGROUND

The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites.

METHODS

We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately.

RESULTS

We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis.

CONCLUSION

BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies.

Для цитирования: Costopoulos Charis, Latib Azeem, Naganuma Toru, Sticchi Alessandro, Ferrarello Santo, Regazzoli Damiano, Chieffo Alaide, Figini Filippo, Carlino Mauro, Montorfano Matteo, Naim Charbel, Kawaguchi Masanori, Gerasimou Argyrios, Giannini Francesco, Godino Cosmo, Colombo Antonio. Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2013. DOI: 10.1002/ccd.25087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.