DOI 10.1016/j.jcin.2012.12.125

Медицинская библиотека · JACC. Cardiovascular interventions · 2013

Final 5-year outcomes from the Endeavor zotarolimus-eluting stent clinical trial program: comparison of safety and efficacy with first-generation drug-eluting and bare-metal stents.

Kandzari David E, Leon Martin B, Meredith Ian, Fajadet Jean, Wijns William, Mauri Laura

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to evaluate late safety and efficacy outcomes among patients enrolled in clinical trials comparing Endeavor zotarolimus-eluting stents (E-ZES) (Medtronic, Inc., Santa Rosa, California) with first-generation drug-eluting stents (DES) and bare-metal stents (BMS).

BACKGROUND

Despite demonstration of higher angiographic luminal loss and restenosis with E-ZES compared with alternative DES, whether differences in these early angiographic measures translate into more disparate late clinical events is uncertain.

METHODS

Among 3,616 patients undergoing percutaneous coronary revascularization in 5 registration trials, late safety and efficacy events were compared between E-ZES (n = 2,132) versus sirolimus- or paclitaxel-eluting stents (n = 888) or BMS (n = 596).

RESULTS

Compared with a parallel cohort of patients treated with first-generation DES and BMS, 5-year rates of cardiac death/myocardial infarction (MI) (5.8% vs. 8.8% DES, p = 0.003; vs. 8.4% BMS, p = 0.02) and major adverse cardiac events (16.1% vs. 20.6% DES, p = 0.009; vs. 24.6% BMS, p < 0.001) were significantly lower with E-ZES. The E-ZES was associated with significantly lower target lesion revascularization (TLR) compared with BMS (7.4% vs. 16.3%, p < 0.001) but similar to comparator DES (7.4% vs. 8.1%, p = 0.63). Despite higher TLR in the first year with E-ZES compared with DES, between 1- and 5-year follow-up, rates of cardiac death/MI, TLR, and definite/probable stent thrombosis were significantly lower with E-ZES.

CONCLUSIONS

Over 5 years, significant differences in cardiac death/MI and composite endpoints favored treatment with E-ZES over comparator BMS and DES. Rates of clinical restenosis and safety events, including stent thrombosis beyond the first year of revascularization, remain stable with E-ZES, leading to significant differences compared with first-generation DES.

Для цитирования: Kandzari David E, Leon Martin B, Meredith Ian, Fajadet Jean, Wijns William, Mauri Laura. Final 5-year outcomes from the Endeavor zotarolimus-eluting stent clinical trial program: comparison of safety and efficacy with first-generation drug-eluting and bare-metal stents.. JACC. Cardiovascular interventions. 2013. DOI: 10.1016/j.jcin.2012.12.125.