Clinical Evidence for Use of a Noninvasive Biosensor for Tear Glucose as an Alternative to Painful Finger-Prick for Diabetes Management Utilizing a Biopolymer Coating.

Kownacka Alicja E, Vegelyte Dovile, Joosse Maurits, Anton Nicoleta, Toebes B Jelle, Lauko Jan, Buzzacchera Irene, Lipinska Katarzyna, Wilson Daniela A, Geelhoed-Duijvestijn Nel, Wilson Christopher J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Diabetes is a metabolic condition that is exponentially increasing worldwide. Current monitoring methods for diabetes are invasive, painful, and expensive. Herein, we present the first multipatient clinical trial that demonstrates clearly that tear fluid may be a valuable marker for systemic glucose measurements. The NovioSense Glucose Sensor, worn under the lower eye lid (inferior conjunctival fornix), is reported to continuously measure glucose levels in the basal tear fluid with good correlation to blood glucose values, showing clear clinical feasibility in both animals and humans. Furthermore, the polysaccharide coated device previously reported by our laboratory when worn, does not induce pain or irritation. In a phase II clinical trial, six patients with type 1 Diabetes Mellitus were enrolled and the capability of the device to measure glucose in the tear fluid was evaluated. The NovioSense Glucose Sensor gives a stable signal and the results correlate well to blood glucose values obtained from finger-prick measurements determined by consensus error grid analysis.

Для цитирования: Kownacka Alicja E, Vegelyte Dovile, Joosse Maurits, Anton Nicoleta, Toebes B Jelle, Lauko Jan, Buzzacchera Irene, Lipinska Katarzyna, Wilson Daniela A, Geelhoed-Duijvestijn Nel, Wilson Christopher J. Clinical Evidence for Use of a Noninvasive Biosensor for Tear Glucose as an Alternative to Painful Finger-Prick for Diabetes Management Utilizing a Biopolymer Coating.. Biomacromolecules. 2018. DOI: 10.1021/acs.biomac.8b01429.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.