OBJECTIVES

Silent cerebral artery vasospasm in aneurysmal subarachnoid hemorrhage causes serious complications such as cerebral ischemia and death. A transcranial Doppler (TCD) ultrasound system is a noninvasive device that can effectively detect cerebral artery vasospasm as soon as it sets in, even before and in the absence of clinical deterioration. Continuous or even daily TCD monitoring is challenging because of the operator expertise and certification required in the form of a trained sonographer and interpretive experience required in the form of an additionally trained and certified physician to perform these studies. This barrier exists because of a lack of automation for detection (without human intervention) of cerebral artery vasospasm using TCD ultrasound. To overcome this barrier, we present an algorithm that automates detection of cerebral artery vasospasm.

METHODS

We extracted features such as the energy, energy entropy, zero-crossing rate, spectral centroid, spectral speed, spectral entropy, spectral flux, spectral roll-off, harmonic ratio, chroma, and Mel frequency cepstral coefficients for signal classification. Then we applied principal component analysis to reduce the data dimensionality.

RESULTS

All of the chosen features were used for training a decision-tree classifier. The algorithm had high accuracy for cerebral artery vasospasm detection, with overall sensitivity of 87.5% and specificity of 89.74%.

CONCLUSIONS

The algorithm has the potential for development into a continuous cerebral artery vasospasm monitor.

Для цитирования: Elzaafarany Khaled, Aly Moustafa H, Kumar Gyanendra, Nakhmani Arie. Cerebral Artery Vasospasm Detection Using Transcranial Doppler Signal Analysis.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2018. DOI: 10.1002/jum.14916.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.